| Assessment Year | 2026 |
|---|---|
| Principal Product | Chemical and Biological Testing Kits |
| NAICS | 325413: In-Vitro Diagnostic Substance Manufacturing |
| SIC | 2835: In Vitro and In Vivo Diagnostic Substances |
| Sales Range | $50 M to 100M |
| # of Employees | 100 |
| Plant Area |
25,000
ft2
|
| Annual Production | 50,000
units
|
| Production Hrs. Annual | 2,250
hrs
|
| Location (State) | Delaware |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $84,449 | 564,976 |
kWh
|
$0.15 | |
| Electricity Demand | $8,440 | 1,156 |
kW-mo/yr
|
$7.30 | |
| Electricity Fees | $2,010 | - |
|
- | |
| LPG | $44,352 | 1,725 |
MMBtu
|
$25.71 | |
| Other Gas | $40 | 1 |
MMBtu
|
$40.00 | |
| Waste Disposal Costs | |||||
| Water Usage | $3,000 | 165 |
Tgal
|
$18.18 | |
| TOTAL YEARLY COSTS | $142,291 | ||||
| RECOMMENDED SAVINGS* | $20,643 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | LPG Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7261: Install timers and/or thermostats | $6,108 | - |
$5,549
37,241
kWh
|
$559
-
kW-mo/yr
|
- | |
| 02 | 2.7261: Install timers and/or thermostats | $8,541 | $220 |
$3,671
24,636
kWh
|
$369
-
kW-mo/yr
|
$4,501
-
MMBtu
|
|
| 03 | 2.2211: Use optimum temperature | $584 | - |
$531
3,564
kWh
|
$53
-
kW-mo/yr
|
- | |
| 04 | 2.6232: Install set-back timers | $362 | $177 |
$329
2,210
kWh
|
$33
-
kW-mo/yr
|
- | |
| 05 | 2.4239: Eliminate or reduce compressed air usage | $641 | $94 |
$583
3,910
kWh
|
$58
-
kW-mo/yr
|
- | |
| 06 | 2.6218: Turn off equipment when not in use | $585 | - |
$531
3,565
kWh
|
$54
-
kW-mo/yr
|
- | |
| 07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $322 | $1,000 |
$292
1,962
kWh
|
$30
-
kW-mo/yr
|
- | |
| 08 | 2.2515: Use optimum thickness insulation | $481 | $474 | - | - |
$481
-
MMBtu
|
|
| 09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,019 | $1,630 |
$2,743
18,406
kWh
|
$277
-
kW-mo/yr
|
- | |
| TOTAL RECOMMENDED | $20,643 | $3,595 |
$14,229
95,494
kWh
|
$1,432
-
kW-mo/yr
|
$4,982
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | LPG Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs