Assessment Year | 2025 |
---|---|
Principal Product | semiconductor-based electronic parts |
NAICS | 334413: Semiconductor and Related Device Manufacturing |
SIC | 3674: Semiconductors and Related Devices |
Sales Range | $1 M to 5M |
# of Employees | 135 |
Plant Area |
27,000
ft2
|
Annual Production | 10,000
units
|
Production Hrs. Annual | 2,500
hrs
|
Location (State) | Delaware |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $121,383 | 871,360 |
kWh
|
$0.14 |
Electricity Demand | $12,471 | 1,453 |
kW-mo/yr
|
$8.58 |
Electricity Fees | $2,806 | - |
|
- |
Natural Gas | $4,469 | 504 |
MMBtu
|
$8.87 |
Other Gas | $1,417 | 1 |
MMBtu
|
$1,417.00 |
TOTAL YEARLY COSTS | $142,546 | |||
RECOMMENDED SAVINGS* | $64,346 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.9114: Use solar heat to make electricty | $58,383 | $470,000 |
$53,049
381,650
kWh
|
$5,334
-
kW-mo/yr
|
- | |
02 | 2.7224: Reduce space conditioning during non-working hours | $4,000 | - |
$4,000
26,149
kWh
|
- | - | |
03 | 2.6231: Utilize controls to operate equipment only when needed | $343 | - |
$311
2,235
kWh
|
$32
-
kW-mo/yr
|
- | |
04 | 2.2211: Use optimum temperature | $1,329 | - | - | - |
$1,329
-
MMBtu
|
|
05 | 2.7261: Install timers and/or thermostats | $291 | $131 |
$122
878
kWh
|
- |
$169
-
MMBtu
|
|
TOTAL RECOMMENDED | $64,346 | $470,131 |
$57,482
410,912
kWh
|
$5,366
-
kW-mo/yr
|
$1,498
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs