| Assessment Year | 2023 |
|---|---|
| Principal Product | Custom metal, plastic parts and Systems |
| NAICS | 332721: Precision Turned Product Manufacturing |
| SIC | 3451: Screw Machine Products |
| Sales Range | $10 M to 50M |
| # of Employees | 41 |
| Plant Area |
45,000
ft2
|
| Annual Production | 500
units
|
| Production Hrs. Annual | 3,000
hrs
|
| Location (State) | New Jersey |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $34,453 | 219,381 |
kWh
|
$0.16 | |
| Electricity Demand | $9,961 | 1,173 |
kW-mo/yr
|
$8.49 | |
| Electricity Fees | $4,509 | - |
|
- | |
| Natural Gas | $8,571 | 726 |
MMBtu
|
$11.81 | |
| Waste Disposal Costs | |||||
| Water Usage | $4,789 | 187 |
Tgal
|
$25.61 | |
| TOTAL YEARLY COSTS | $62,283 | ||||
| RECOMMENDED SAVINGS* | $15,910 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | $4,704 | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Usage Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 3.4156: Use flow control valves on equipment to optimize water use | $1,009 | $42 | - | - | - |
$1,009
-
Tgal
|
|
| 02 | 2.6232: Install set-back timers | $245 | $130 |
$192
1,226
kWh
|
$53
-
kW-mo/yr
|
- | - | |
| 03 | 2.4322: Use or replace with energy efficient substitutes | $338 | $9,500 |
$266
1,692
kWh
|
$72
-
kW-mo/yr
|
- | - | |
| 04 | 2.6212: Turn off equipment during breaks, reduce operating time | $413 | - | - | - |
$413
-
MMBtu
|
- | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $402 | $871 |
$316
2,011
kWh
|
$86
-
kW-mo/yr
|
- | - | |
| 06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,097 | $3,000 |
$861
5,488
kWh
|
$236
-
kW-mo/yr
|
- | - | |
| 07 | 2.4226: Use / purchase optimum sized compressor | $4,366 | $25,000 |
$3,124
19,897
kWh
|
$895
-
kW-mo/yr
|
$347
-
MMBtu
|
- | |
| 08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,152 | $4,581 |
$4,782
30,455
kWh
|
$1,370
-
kW-mo/yr
|
- | - | |
| 09 | 2.7493: Use double or triple glazed windows to maintain higher relative humidity and to reduce heat losses | $1,888 | $2,450 | - | - |
$1,888
-
MMBtu
|
- | |
| TOTAL RECOMMENDED | $15,910 | $45,574 |
$9,541
60,769
kWh
|
$2,712
-
kW-mo/yr
|
$2,648
-
MMBtu
|
$1,009
-
Tgal
|
||
| TOTAL IMPLEMENTED | $4,704 | $34,500 |
$3,390
21,589
kWh
|
$967
-
kW-mo/yr
|
$347
-
MMBtu
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Usage Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs