Assessment Year | 2022 |
---|---|
Principal Product | Printed products, brochures |
NAICS | 323111: Commercial Printing (except Screen and Books) |
SIC | 2754: Commercial Printing, Gravure |
Sales Range | $10 M to 50M |
# of Employees | 50 |
Plant Area |
53,067
ft2
|
Annual Production | 20,000
units
|
Production Hrs. Annual | 3,500
hrs
|
Location (State) | Delaware |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $66,015 | 890,603 |
kWh
|
$0.074 | |
Electricity Demand | $21,040 | 3,359 |
kW-mo/yr
|
$6.26 | |
Electricity Fees | $1,800 | - |
|
- | |
Natural Gas | $5,098 | 611 |
MMBtu
|
$8.34 | |
Waste Disposal Costs | |||||
Water Usage | $1,545 | 85 |
Tgal
|
$18.18 | |
TOTAL YEARLY COSTS | $95,498 | ||||
RECOMMENDED SAVINGS* | $34,207 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $24,123 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.6218: Turn off equipment when not in use | $3,922 | - |
$3,922
40,022
kWh
|
- | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $175 | $500 |
$175
1,789
kWh
|
- | |
03 | 2.6218: Turn off equipment when not in use | $93 | - |
$93
948
kWh
|
- | |
04 | 2.6218: Turn off equipment when not in use | $1,065 | - |
$243
2,475
kWh
|
$822
-
MMBtu
|
|
05 | 2.7243: Improve air circulation with destratification fans / other methods | $4,575 | $971 |
$2,621
26,743
kWh
|
$1,954
-
MMBtu
|
|
06 | 2.7261: Install timers and/or thermostats | $638 | $423 | - |
$638
-
MMBtu
|
|
07 | 2.6231: Utilize controls to operate equipment only when needed | $68 | - |
$68
695
kWh
|
- | |
08 | 2.6232: Install set-back timers | $1,842 | - |
$1,163
11,869
kWh
|
$679
-
MMBtu
|
|
09 | 2.6231: Utilize controls to operate equipment only when needed | $169 | - |
$169
1,726
kWh
|
- | |
10 | 2.6211: Conserve energy by efficient use of vending machines | $129 | $18 |
$129
1,316
kWh
|
- | |
11 | 2.6242: Minimize operation of equipment maintained in standby condition | $263 | - |
$263
2,683
kWh
|
- | |
12 | 2.6231: Utilize controls to operate equipment only when needed | $1,102 | $4,000 |
$1,102
11,246
kWh
|
- | |
13 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $611 | $870 |
$611
6,232
kWh
|
- | |
14 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,020 | $5,605 |
$5,020
51,230
kWh
|
- | |
15 | 2.7228: Avoid introducing hot, humid, or dirty air into hvac system | $14,535 | $2,912 |
$14,535
148,320
kWh
|
- | |
TOTAL RECOMMENDED | $34,207 | $15,299 |
$30,114
307,294
kWh
|
$4,093
-
MMBtu
|
||
TOTAL IMPLEMENTED | $24,123 | $10,310 |
$21,984
224,336
kWh
|
$2,139
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs