Assessment Year | 2020 |
---|---|
Principal Product | Cooling Towers & Related Parts |
NAICS | 333415: Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipmen |
SIC | 3444: Sheet Metal Work |
Sales Range | $50 M to 100M |
# of Employees | 350 |
Plant Area |
170,000
ft2
|
Annual Production | 1,600
units
|
Production Hrs. Annual | 6,600
hrs
|
Location (State) | Delaware |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $349,311 | 4,939,200 |
kWh
|
$0.071 |
Electricity Demand | $114,961 | 12,592 |
kW-mo/yr
|
$9.13 |
Electricity Fees | $2,640 | - |
|
- |
Natural Gas | $135,960 | 20,176 |
MMBtu
|
$6.74 |
TOTAL YEARLY COSTS | $602,872 | |||
RECOMMENDED SAVINGS* | $111,470 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $39,830 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7314: Reduce ventilation air | $26,710 | - |
$3,680
39,960
kWh
|
$23,030
-
MMBtu
|
|
02 | 2.7261: Install timers and/or thermostats | $980 | $120 | - |
$980
-
MMBtu
|
|
03 | 2.7311: Ventilation system to shut off when room is not in use | $1,450 | $400 |
$320
3,490
kWh
|
$1,130
-
MMBtu
|
|
04 | 2.6231: Utilize controls to operate equipment only when needed | $7,160 | $1,600 |
$7,160
77,880
kWh
|
- | |
05 | 2.6231: Utilize controls to operate equipment only when needed | $7,970 | $5,800 |
$7,970
86,610
kWh
|
- | |
06 | 2.6231: Utilize controls to operate equipment only when needed | $3,050 | $4,000 |
$3,050
33,160
kWh
|
- | |
07 | 2.2523: Reduce infiltration to refrigerated areas; isolate hot equipment from refrigerated areas | $53,460 | $2,400 | - |
$53,460
-
MMBtu
|
|
08 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $10,080 | $1,900 |
$10,080
109,600
kWh
|
- | |
09 | 2.6242: Minimize operation of equipment maintained in standby condition | $610 | $900 |
$610
6,600
kWh
|
- | |
TOTAL RECOMMENDED | $111,470 | $17,120 |
$32,870
357,300
kWh
|
$78,600
-
MMBtu
|
||
TOTAL IMPLEMENTED | $39,830 | $3,320 |
$14,690
159,650
kWh
|
$25,140
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs