Assessment Year | 2008 |
---|---|
Principal Product | Protective masks, enclosures, space suits and aerostats |
NAICS | 336411: Aircraft Manufacturing |
SIC | 3842: Orthopedic, Prosthetic, and Surgical Appliances and Supplies |
Sales Range | $50 M to 100M |
# of Employees | 350 |
Plant Area |
274,031
ft2
|
Annual Production | 245,025
pieces
|
Production Hrs. Annual | 2,210
hrs
|
Location (State) | Delaware |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $508,175 | 4,263,301 |
kWh
|
$0.12 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $110,115 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $83,877 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.6218: Turn off equipment when not in use | $38,000 | - |
$38,000
330,000
kWh
|
|
02 | 2.7221: Lower temperature during the winter season and vice-versa | $15,500 | - |
$15,500
133,620
kWh
|
|
03 | 2.2437: Recover waste heat from equipment | $11,841 | $1,430 |
$11,841
96,972
kWh
|
|
04 | 2.7314: Reduce ventilation air | $9,470 | - |
$9,470
81,600
kWh
|
|
05 | 2.4221: Install compressor air intakes in coolest locations | $3,327 | $640 |
$3,327
28,681
kWh
|
|
06 | 2.4226: Use / purchase optimum sized compressor | $1,600 | $2,800 |
$1,600
14,000
kWh
|
|
07 | 2.7232: Replace existing hvac unit with high efficiency model | $23,000 | $40,000 |
$23,000
269,000
kWh
|
|
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $7,377 | $45,000 |
$7,377
63,591
kWh
|
|
TOTAL RECOMMENDED | $110,115 | $89,870 |
$110,115
1,017,464
kWh
|
||
TOTAL IMPLEMENTED | $83,877 | $85,000 |
$83,877
796,211
kWh
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs