Assessment Year | 2008 |
---|---|
Principal Product | Fabricated Architectural Glass |
NAICS | 339999: All Other Miscellaneous Manufacturing |
SIC | 5039: Construction Materials, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 250 |
Plant Area |
183,000
ft2
|
Annual Production | 16,000
thousand feet
|
Production Hrs. Annual | 7,488
hrs
|
Location (State) | New Jersey |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $731,400 | 731,400 |
kWh
|
$1.00 |
Electricity Demand | $43,400 | 43,400 |
kW-mo/yr
|
$1.00 |
Natural Gas | $167 | 12,330 |
MMBtu
|
$0.014 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $103,668 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $15,917 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.4224: Upgrade controls on compressors | $19,500 | $1,000 |
$19,500
150,000
kWh
|
- | |
02 | 2.6218: Turn off equipment when not in use | $12,550 | - |
$10,800
83,000
kWh
|
$1,750
-
kW-mo/yr
|
|
03 | 2.6231: Utilize controls to operate equipment only when needed | $11,172 | $700 |
$11,172
85,938
kWh
|
- | |
04 | 2.7135: Install occupancy sensors | $3,343 | $590 |
$3,343
25,718
kWh
|
- | |
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,304 | $500 |
$2,304
17,725
kWh
|
- | |
06 | 2.4221: Install compressor air intakes in coolest locations | $635 | $160 |
$635
4,887
kWh
|
- | |
07 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $24 | $2,394 |
$24
10,290
kWh
|
- | |
08 | 2.2414: Use waste heat from hot flue gases to preheat | $38,540 | $125,000 |
$38,540
2,840
kWh
|
- | |
09 | 2.9114: Use solar heat to make electricty | $15,600 | $600,000 |
$15,600
120,000
kWh
|
- | |
TOTAL RECOMMENDED | $103,668 | $730,344 |
$101,918
500,398
kWh
|
$1,750
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $15,917 | $2,984 |
$14,167
119,008
kWh
|
$1,750
-
kW-mo/yr
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs