Assessment Year | 2013 |
---|---|
Principal Product | Diamond cutting wire |
NAICS | 332813: Electroplating, Plating, Polishing, Anodizing, and Coloring |
SIC | 3471: Electroplating, Plating, Polishing, Anodizing, and Coloring |
Sales Range | $10 M to 50M |
# of Employees | 145 |
Plant Area |
132,000
ft2
|
Annual Production | 50,000
pieces
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Colorado |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $152,497 | 5,209,729 |
kWh
|
$0.029 |
Electricity Demand | $164,375 | 8,825 |
kW-mo/yr
|
$18.63 |
Electricity Fees | $6,843 | - |
|
- |
Natural Gas | $79,085 | 9,679 |
MMBtu
|
$8.17 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $41,060 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $270 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7252: Utilize an evaporative air pre-cooler or other heat exchanger in ac system | $30,250 | $172,320 |
$10,180
319,200
kWh
|
$20,070
-
kW-mo/yr
|
- | - | - | |
02 | 2.7232: Replace existing hvac unit with high efficiency model | $9,730 | $18,100 | - | - |
$9,730
-
MMBtu
|
- | - | |
03 | 2.7135: Install occupancy sensors | $810 | $1,280 |
$570
26,400
kWh
|
- | - | $170 | $70 | |
04 | 2.7447: Install vinyl strip / high speed / air curtain doors | $270 | $290 | - | - |
$270
-
MMBtu
|
- | - | |
TOTAL RECOMMENDED | $41,060 | $191,990 |
$10,750
345,600
kWh
|
$20,070
-
kW-mo/yr
|
$10,000
-
MMBtu
|
$170 | $70 | ||
TOTAL IMPLEMENTED | $270 | $290 | - | - |
$270
-
MMBtu
|
- | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs