ITAC Assessment: CO0558
ITAC logo
ITAC Assessment: CO0558
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2005
Principal Product Bath and shower enclosures
NAICS 327215: Glass Product Manufacturing Made of Purchased Glass
SIC 3231: Glass Products, Made of Purchased Glass
Sales Range $10
M
to 50
M
# of Employees 67
Plant Area 45,000
ft2
Annual Production 30,000
pieces
Production Hrs. Annual 6,240
hrs
Location (State) Colorado

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $103,953 2,703,000
kWh
Electricity Demand $49,717 8,965
kW-mo/yr
Electricity Fees $1,618 -
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $10,414 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $7,604

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Ancillary Material Cost Savings
01 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,990 $350 $1,350
34,900
kWh
$640
-
kW-mo/yr
-
02 2.4226: Use / purchase optimum sized compressor $1,700 $2,720 $1,150
30,000
kWh
$550
-
kW-mo/yr
-
03 2.4111: Utilize energy-efficient belts and other improved mechanisms $1,020 $6,030 $650
17,000
kWh
$370
-
kW-mo/yr
-
04 2.4133: Use most efficient type of electric motors $234 $588 $149
3,886
kWh
$85
-
kW-mo/yr
-
05 2.7447: Install vinyl strip / high speed / air curtain doors $2,810 $1,910 $2,540
66,200
kWh
$270
-
kW-mo/yr
-
06 2.7142: Utilize higher efficiency lamps and/or ballasts $2,660 $7,410 $2,100
54,500
kWh
$1,000
-
kW-mo/yr
$(-440.0)
TOTAL RECOMMENDED $10,414 $19,008 $7,939
206,486
kWh
$2,915
-
kW-mo/yr
$(-440.0)
TOTAL IMPLEMENTED $7,604 $17,098 $5,399
140,286
kWh
$2,645
-
kW-mo/yr
$(-440.0)
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs