Assessment Year | 1994 |
---|---|
Principal Product | wood preservatives |
NAICS |
n/a
|
SIC | 2842: Specialty Cleaning, Polishing, and Sanitation Preparations |
Sales Range | $10 M to 50M |
# of Employees | 150 |
Plant Area |
124,850
ft2
|
Annual Production | 12,700,000
pieces
|
Production Hrs. Annual | 2,210
hrs
|
Location (State) | Colorado |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $179,420 | 2,778,722 |
kWh
|
$0.065 |
Natural Gas | $53,510 | 12,771 |
MMBtu
|
$4.19 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $11,560 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $6,610 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.8121: Apply for tax-free status for energy purchases | $4,670 | $250 | - | - | $4,670 | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,540 | $6,360 |
$2,540
39,273
kWh
|
- | - | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,940 | $160 |
$1,940
30,188
kWh
|
- | - | |
04 | 2.4221: Install compressor air intakes in coolest locations | $1,050 | $500 |
$1,050
16,120
kWh
|
- | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,020 | $4,520 |
$1,020
15,826
kWh
|
- | - | |
06 | 2.7444: Close holes and openings in building such as broken windows | $340 | $980 | - |
$340
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $11,560 | $12,770 |
$6,550
101,407
kWh
|
$340
-
MMBtu
|
$4,670 | ||
TOTAL IMPLEMENTED | $6,610 | $410 |
$1,940
30,188
kWh
|
- | $4,670 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs