Assessment Year | 1993 |
---|---|
Principal Product | Carbon fiber textiles |
NAICS |
n/a
|
SIC | 2299: Textile goods, Not Elsewhere Classified |
Sales Range | $5 M to 10M |
# of Employees | 27 |
Plant Area |
12,600
ft2
|
Annual Production | 300,000
lb
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Colorado |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $82,241 | 2,065,358 |
kWh
|
$0.040 |
Natural Gas | $1,454 | 531 |
MMBtu
|
$2.74 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $3,580 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $1,420 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $580 | $2,000 |
$580
14,654
kWh
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,190 | $2,970 |
$1,190
29,894
kWh
|
- | |
03 | 2.4221: Install compressor air intakes in coolest locations | $980 | $1,420 |
$980
24,619
kWh
|
- | |
04 | 2.4314: Use synthetic lubricant | $600 | $100 |
$600
15,240
kWh
|
- | |
05 | 2.7226: Use computer programs to optimize hvac performance | $230 | $40 |
$120
4,396
kWh
|
$110
-
MMBtu
|
|
TOTAL RECOMMENDED | $3,580 | $6,530 |
$3,470
88,803
kWh
|
$110
-
MMBtu
|
||
TOTAL IMPLEMENTED | $1,420 | $3,010 |
$1,310
34,290
kWh
|
$110
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs