Assessment Year | 1993 |
---|---|
Principal Product | Aircraft crew seats |
NAICS |
n/a
|
SIC | 3728: Aircraft Parts and Auxiliary Equipment, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 183 |
Plant Area |
115,000
ft2
|
Annual Production | 1,128
pieces
|
Production Hrs. Annual | 5,746
hrs
|
Location (State) | Colorado |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $149,751 | 3,291,032 |
kWh
|
$0.046 |
Natural Gas | $43,007 | 11,171 |
MMBtu
|
$3.85 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $124,090 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings | Primary Raw Material Savings |
---|---|---|---|---|---|---|---|---|
01 | 3.2123: Convert to high volume low pressure (hvlp) paint guns | $92,610 | $6,220 | - | - | - | $92,610 | |
02 | 2.2437: Recover waste heat from equipment | $9,680 | $2,010 | - |
$9,680
-
MMBtu
|
- | - | |
03 | 2.4239: Eliminate or reduce compressed air usage | $5,720 | $8,500 |
$5,720
125,733
kWh
|
- | - | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,170 | $7,020 |
$5,170
113,716
kWh
|
- | - | - | |
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,840 | $130 |
$1,840
40,445
kWh
|
- | - | - | |
06 | 2.2511: Insulate bare equipment | $1,400 | $480 |
$1,400
30,774
kWh
|
- | - | - | |
07 | 2.7261: Install timers and/or thermostats | $1,540 | $750 |
$770
28,136
kWh
|
$770
-
MMBtu
|
- | - | |
08 | 2.4221: Install compressor air intakes in coolest locations | $1,540 | $1,000 |
$1,540
33,998
kWh
|
- | - | - | |
09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,470 | $3,320 |
$1,470
32,239
kWh
|
- | - | - | |
10 | 2.4133: Use most efficient type of electric motors | $1,290 | $2,790 |
$1,290
28,429
kWh
|
- | - | - | |
11 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $860 | $400 |
$860
18,757
kWh
|
- | - | - | |
12 | 2.3137: Use power during off-peak periods | $660 | $120 | - | - | $660 | - | |
13 | 2.7134: Use photocell controls | $310 | $560 |
$310
6,741
kWh
|
- | - | - | |
TOTAL RECOMMENDED | $124,090 | $33,300 |
$20,370
458,968
kWh
|
$10,450
-
MMBtu
|
$660 | $92,610 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings | Primary Raw Material Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs