Assessment Year 1993
Principal Product Cement
NAICS
n/a
SIC 3241: Cement, Hydraulic
Sales Range $10
M
to 50
M
# of Employees 83
Plant Area 73,000
ft2
Annual Production 400,000
ton
Production Hrs. Annual 8,736
hrs
Location (State) Colorado

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $3,280,001 75,441,971
kWh
Natural Gas $3,309,407 1,663,019
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $4,201,770 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $1,374,840

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings Administrative Changes Savings
01 2.3413: Burn fossil fuel to produce steam to drive a steam turbine-generator and use steam exhaust for heat $2,405,000 $6,313,000 $2,405,000
55,318,289
kWh
- -
02 2.1331: Burn a less expensive grade of fuel $1,287,000 $325,000 - - $1,287,000
03 2.2428: Use flue gases in radiant heater for space heating, ovens, etc $332,600 $250,000 - $332,600
-
MMBtu
-
04 2.7444: Close holes and openings in building such as broken windows $87,840 $1,000 - $87,840
-
MMBtu
-
05 2.4133: Use most efficient type of electric motors $81,180 $144,120 $81,180
1,867,526
kWh
- -
06 2.4314: Use synthetic lubricant $6,180 - $6,180
142,145
kWh
- -
07 2.7142: Utilize higher efficiency lamps and/or ballasts $1,290 $1,590 $1,290
29,601
kWh
- -
08 2.7142: Utilize higher efficiency lamps and/or ballasts $430 $960 $430
9,965
kWh
- -
09 2.7261: Install timers and/or thermostats $250 $150 $190
9,086
kWh
$60
-
MMBtu
-
TOTAL RECOMMENDED $4,201,770 $7,035,820 $2,494,270
57,376,612
kWh
$420,500
-
MMBtu
$1,287,000
TOTAL IMPLEMENTED $1,374,840 $326,000 - $87,840
-
MMBtu
$1,287,000
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs