Assessment Year | 1991 |
---|---|
Principal Product | WIRE COATING |
NAICS |
n/a
|
SIC | 3643: Current-Carrying Wiring Devices |
Sales Range | $10 M to 50M |
# of Employees | 90 |
Plant Area |
n/a
|
Annual Production | 5
thousand feet
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Nebraska |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $243,727 | 4,150,059 |
kWh
|
$0.059 |
Natural Gas | $14,774 | 3,520 |
MMBtu
|
$4.20 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $3,568 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.4221: Install compressor air intakes in coolest locations | $1,300 | $800 |
$1,300
22,860
kWh
|
- | |
02 | 2.8121: Apply for tax-free status for energy purchases | $760 | $250 | - |
$760
-
MMBtu
|
|
03 | 2.7261: Install timers and/or thermostats | $470 | $500 |
$200
7,034
kWh
|
$270
-
MMBtu
|
|
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $353 | $367 |
$353
6,155
kWh
|
- | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $210 | $770 |
$210
3,517
kWh
|
- | |
06 | 2.4133: Use most efficient type of electric motors | $475 | $1,060 |
$475
7,913
kWh
|
- | |
TOTAL RECOMMENDED | $3,568 | $3,747 |
$2,538
47,479
kWh
|
$1,030
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs