Assessment Year 1991
Principal Product METAL WORKING MACHINERY
NAICS
n/a
SIC 3542: Machine Tools, Metal Forming Types
Sales Range $10
M
to 50
M
# of Employees 185
Plant Area
n/a
Annual Production 1,500,000
lb
Production Hrs. Annual 5,200
hrs
Location (State) Colorado

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $89,345 1,552,462
kWh
Natural Gas $39,280 10,176
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $4,734 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $4,734

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.4221: Install compressor air intakes in coolest locations $1,100 $700 $1,100
19,050
kWh
-
02 2.4133: Use most efficient type of electric motors $551 $1,625 $551
9,379
kWh
-
03 2.7261: Install timers and/or thermostats $550 $1,500 - $550
-
MMBtu
04 2.7142: Utilize higher efficiency lamps and/or ballasts $2,533 $1,100 $2,533
43,962
kWh
-
TOTAL RECOMMENDED $4,734 $4,925 $4,184
72,391
kWh
$550
-
MMBtu
TOTAL IMPLEMENTED $4,734 $4,925 $4,184
72,391
kWh
$550
-
MMBtu