| Assessment Year | 1988 |
|---|---|
| Principal Product | FLUID MILK AND CHEESE |
| NAICS |
n/a
|
| SIC | 2026: Fluid Milk |
| Sales Range | $50 M to 100M |
| # of Employees | 160 |
| Plant Area |
n/a
|
| Annual Production | 13,000
Tgal
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | Colorado |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $254,654 | 5,822,099 |
kWh
|
$0.044 |
| Natural Gas | $91,754 | 27,038 |
MMBtu
|
$3.39 |
| Fuel Oil #2 | $13,750 | 3,500 |
MMBtu
|
$3.93 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $31,149 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $25,135 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Fuel Oil #2 Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.1233: Analyze flue gas for proper air/fuel ratio | $2,422 | $2,000 | - |
$2,075
-
MMBtu
|
$347
-
MMBtu
|
- | |
| 02 | 2.2414: Use waste heat from hot flue gases to preheat | $8,808 | $12,000 | - |
$7,547
-
MMBtu
|
$1,261
-
MMBtu
|
- | |
| 03 | 2.2447: Heat water with exhaust heat | $3,080 | $5,500 | - |
$2,639
-
MMBtu
|
$441
-
MMBtu
|
- | |
| 04 | 2.2121: Increase amount of condensate returned | $1,681 | $1,635 | - |
$785
-
MMBtu
|
$131
-
MMBtu
|
$765 | |
| 05 | 2.2511: Insulate bare equipment | $362 | $870 | - |
$310
-
MMBtu
|
$52
-
MMBtu
|
- | |
| 06 | 2.2136: Install / repair insulation on steam lines | $1,496 | $1,260 | - |
$1,282
-
MMBtu
|
$214
-
MMBtu
|
- | |
| 07 | 2.7492: Use proper thickness of insulation on building envelope | $512 | $1,480 | - |
$512
-
MMBtu
|
- | - | |
| 08 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,340 | - |
$2,340
53,634
kWh
|
- | - | - | |
| 09 | 2.4221: Install compressor air intakes in coolest locations | $2,394 | $400 |
$2,394
54,807
kWh
|
- | - | - | |
| 10 | 2.7261: Install timers and/or thermostats | $1,039 | $1,050 | - |
$960
-
MMBtu
|
$79
-
MMBtu
|
- | |
| 11 | 2.8121: Apply for tax-free status for energy purchases | $6,470 | $350 |
$6,200
-
kWh
|
$270
-
MMBtu
|
- | - | |
| 12 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $545 | $402 |
$545
12,603
kWh
|
- | - | - | |
| TOTAL RECOMMENDED | $31,149 | $26,947 |
$11,479
121,044
kWh
|
$16,380
-
MMBtu
|
$2,525
-
MMBtu
|
$765 | ||
| TOTAL IMPLEMENTED | $25,135 | $17,967 |
$11,479
121,044
kWh
|
$11,154
-
MMBtu
|
$1,737
-
MMBtu
|
$765 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Fuel Oil #2 Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs