Assessment Year | 1987 |
---|---|
Principal Product | CORRUGATED PAPER PRODCTS |
NAICS |
n/a
|
SIC | 2653: Corrugated and Solid Fiber Boxes |
Sales Range | $10 M to 50M |
# of Employees | 130 |
Plant Area |
n/a
|
Annual Production | 472,000
thousand feet
|
Production Hrs. Annual | 4,160
hrs
|
Location (State) | Colorado |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $167,408 | 2,915,885 |
kWh
|
$0.057 |
Natural Gas | $214,416 | 53,192 |
MMBtu
|
$4.03 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $32,795 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $17,682 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.3191: Use demand controller or load shedder | $1,434 | $1,200 |
$1,434
-
kWh
|
- | |
02 | 2.7447: Install vinyl strip / high speed / air curtain doors | $480 | $125 | - |
$480
-
MMBtu
|
|
03 | 2.7492: Use proper thickness of insulation on building envelope | $406 | $1,000 | - |
$406
-
MMBtu
|
|
04 | 2.2122: Install / repair insulation on condensate lines | $1,279 | $2,690 | - |
$1,279
-
MMBtu
|
|
05 | 2.2122: Install / repair insulation on condensate lines | $109 | $70 | - |
$109
-
MMBtu
|
|
06 | 2.1233: Analyze flue gas for proper air/fuel ratio | $6,787 | $300 | - |
$6,787
-
MMBtu
|
|
07 | 2.1213: Direct warmest air to combustion intake | $1,065 | $400 | - |
$1,065
-
MMBtu
|
|
08 | 2.2135: Repair and eliminate steam leaks | $2,521 | $300 | - |
$2,521
-
MMBtu
|
|
09 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,732 | $150 |
$1,732
30,188
kWh
|
- | |
10 | 2.4221: Install compressor air intakes in coolest locations | $609 | $180 |
$609
10,551
kWh
|
- | |
11 | 2.4133: Use most efficient type of electric motors | $374 | $1,167 |
$374
6,448
kWh
|
- | |
12 | 2.7221: Lower temperature during the winter season and vice-versa | $14,707 | $1,100 |
$123
2,052
kWh
|
$14,584
-
MMBtu
|
|
13 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,292 | $409 |
$1,292
22,567
kWh
|
- | |
TOTAL RECOMMENDED | $32,795 | $9,091 |
$5,564
71,806
kWh
|
$27,231
-
MMBtu
|
||
TOTAL IMPLEMENTED | $17,682 | $6,991 |
$5,441
69,754
kWh
|
$12,241
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs