| Assessment Year | 1987 | 
|---|---|
| Principal Product | SPEED REDUCTION EQUIP | 
| NAICS | 
                             n/a 
                     | 
    
| SIC | 3566: Speed Changers, Industrial High-Speed Drives, and Gears | 
| Sales Range | $10 M  to 50M  | 
    
| # of Employees | 200 | 
| Plant Area | 
                             n/a 
                     | 
    
| Annual Production | 70,000
             
pieces
 
         | 
    
| Production Hrs. Annual | 7,488
             
hrs
 
         | 
    
| Location (State) | Colorado | 
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $183,761 | 3,670,868 | 
             
kWh
 
         | 
        $0.050 | 
| Natural Gas | $56,074 | 13,101 | 
             
MMBtu
 
         | 
        $4.28 | 
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $22,886 | 
             See individual recommendations below 
            *Non-energy impacts included in savings.
         | 
    ||
| IMPLEMENTED SAVINGS* | $18,144 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | 
|---|---|---|---|---|---|---|
| 01 | 2.4221: Install compressor air intakes in coolest locations | $1,461 | $500 | 
                        $1,461
                                                     29,308
                                 
                                            
kWh
 
                             | 
                                                                                - | |
| 02 | 2.2437: Recover waste heat from equipment | $2,213 | $3,000 | - | 
                        $2,213
                                                     -
                                 
                                            
MMBtu
 
                             | 
                                    |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,081 | $250 | 
                        $3,081
                                                     61,547
                                 
                                            
kWh
 
                             | 
                                                                                - | |
| 04 | 2.3132: Recharge batteries on during off-peak demand periods | $1,490 | $2,000 | 
                        $1,490
                                                     -
                                 
                                            
kWh
 
                             | 
                                                                                - | |
| 05 | 2.1221: Replace obsolete burners with more efficient ones | $2,800 | $13,500 | - | 
                        $2,800
                                                     -
                                 
                                            
MMBtu
 
                             | 
                                    |
| 06 | 2.7314: Reduce ventilation air | $300 | $36 | 
                        $107
                                                     2,052
                                 
                                            
kWh
 
                             | 
                                                                                
                        $193
                                                     -
                                 
                                            
MMBtu
 
                             | 
                                    |
| 07 | 2.2511: Insulate bare equipment | $187 | $60 | - | 
                        $187
                                                     -
                                 
                                            
MMBtu
 
                             | 
                                    |
| 08 | 2.7492: Use proper thickness of insulation on building envelope | $2,609 | $10,000 | - | 
                        $2,609
                                                     -
                                 
                                            
MMBtu
 
                             | 
                                    |
| 09 | 2.7492: Use proper thickness of insulation on building envelope | $149 | $525 | - | 
                        $149
                                                     -
                                 
                                            
MMBtu
 
                             | 
                                    |
| 10 | 2.7243: Improve air circulation with destratification fans / other methods | $1,942 | $4,800 | 
                        $(-307.0)
                                                     (-6,155)
                                 
                                            
kWh
 
                             | 
                                                                                
                        $2,249
                                                     -
                                 
                                            
MMBtu
 
                             | 
                                    |
| 11 | 2.7261: Install timers and/or thermostats | $2,841 | $474 | 
                        $299
                                                     5,862
                                 
                                            
kWh
 
                             | 
                                                                                
                        $2,542
                                                     -
                                 
                                            
MMBtu
 
                             | 
                                    |
| 12 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,813 | $2,762 | 
                        $3,813
                                                     76,202
                                 
                                            
kWh
 
                             | 
                                                                                - | |
| TOTAL RECOMMENDED | $22,886 | $37,907 | 
                        $9,944
                                                     168,816
                                 
                                            
kWh
 
                             | 
                                                                                
                        $12,942
                                                     -
                                 
                                            
MMBtu
 
                             | 
                                    ||
| TOTAL IMPLEMENTED | $18,144 | $19,607 | 
                        $10,251
                                                     174,971
                                 
                                            
kWh
 
                             | 
                                                                                
                        $7,893
                                                     -
                                 
                                            
MMBtu
 
                             | 
                                    ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs