ITAC Assessment: CO0085
ITAC logo
ITAC Assessment: CO0085
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1987
Principal Product FILTERS, LUBRICATORS
NAICS
n/a
SIC 3567: Industrial Process Furnaces and Ovens
Sales Range $10
M
to 50
M
# of Employees 300
Plant Area
n/a
Annual Production 850,000
pieces
Production Hrs. Annual 6,240
hrs
Location (State) Colorado

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $264,214 4,642,145
kWh
Natural Gas $52,945 11,837
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $31,074 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $15,107

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.1233: Analyze flue gas for proper air/fuel ratio $980 $400 - $980
-
MMBtu
02 2.7316: Centralize control of exhaust fans to ensure their shutdown, or establish program to ensure manual shutdown $1,316 $370 $489
8,499
kWh
$827
-
MMBtu
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,860 $300 $1,860
32,825
kWh
-
04 2.3191: Use demand controller or load shedder $8,426 $5,900 $8,426
-
kWh
-
05 2.4312: Improve lubrication practices $2,514 - $2,514
44,256
kWh
-
06 2.4133: Use most efficient type of electric motors $437 $1,745 $437
7,620
kWh
-
07 2.7261: Install timers and/or thermostats $1,558 $800 - $1,558
-
MMBtu
08 2.7226: Use computer programs to optimize hvac performance $5,303 $12,500 $5,303
93,200
kWh
-
09 2.7447: Install vinyl strip / high speed / air curtain doors $1,417 $428 $202
3,517
kWh
$1,215
-
MMBtu
10 2.7492: Use proper thickness of insulation on building envelope $255 $520 - $255
-
MMBtu
11 2.7231: Use radiant heater for spot heating $871 $4,600 - $871
-
MMBtu
12 2.7142: Utilize higher efficiency lamps and/or ballasts $6,137 $2,250 $6,137
107,855
kWh
-
TOTAL RECOMMENDED $31,074 $29,813 $25,368
297,772
kWh
$5,706
-
MMBtu
TOTAL IMPLEMENTED $15,107 $18,243 $12,079
212,192
kWh
$3,028
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs