Assessment Year | 1995 |
---|---|
Principal Product | instrumentation equipment |
NAICS |
n/a
|
SIC | 3491: Industrial Valves |
Sales Range | $10 M to 50M |
# of Employees | 276 |
Plant Area |
204,000
ft2
|
Annual Production | 2,000
pieces
|
Production Hrs. Annual | 4,420
hrs
|
Location (State) | Iowa |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $385,238 | 6,985,639 |
kWh
|
$0.055 |
Natural Gas | $55,282 | 14,756 |
MMBtu
|
$3.75 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $54,424 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $49,368 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.4321: Upgrade obsolete equipment | $43,805 | $124,000 |
$43,805
341,149
kWh
|
- | |
02 | 2.7314: Reduce ventilation air | $2,054 | $975 |
$2,054
37,222
kWh
|
- | |
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,064 | $25 |
$2,064
37,515
kWh
|
- | |
04 | 2.2437: Recover waste heat from equipment | $886 | $320 | - |
$886
-
MMBtu
|
|
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $967 | $2,222 |
$967
17,585
kWh
|
- | |
06 | 2.7135: Install occupancy sensors | $1,238 | $2,071 |
$1,238
22,567
kWh
|
- | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,106 | $2,454 |
$2,106
38,101
kWh
|
- | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,304 | $341 |
$1,304
23,740
kWh
|
- | |
TOTAL RECOMMENDED | $54,424 | $132,408 |
$53,538
517,879
kWh
|
$886
-
MMBtu
|
||
TOTAL IMPLEMENTED | $49,368 | $129,609 |
$49,368
442,263
kWh
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs