Assessment Year 1986
Principal Product CORRUGATED BOXES
NAICS
n/a
SIC 2653: Corrugated and Solid Fiber Boxes
Sales Range $10
M
to 50
M
# of Employees 90
Plant Area
n/a
Annual Production 325,000
thousand feet
Production Hrs. Annual 4,420
hrs
Location (State) Colorado

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $125,473 2,210,141
kWh
Natural Gas $141,078 35,446
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $47,577 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $29,735

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $11,565 $500 $11,565
203,693
kWh
-
02 2.1233: Analyze flue gas for proper air/fuel ratio $10,145 $300 - $10,145
-
MMBtu
03 2.7243: Improve air circulation with destratification fans / other methods $7,035 $5,500 $(-483.0)
(-8,499)
kWh
$7,518
-
MMBtu
04 2.2414: Use waste heat from hot flue gases to preheat $4,931 $6,400 - $4,931
-
MMBtu
05 2.2135: Repair and eliminate steam leaks $2,145 $1,000 - $2,145
-
MMBtu
06 2.2121: Increase amount of condensate returned $820 $400 - $820
-
MMBtu
07 2.4312: Improve lubrication practices $3,461 - $3,461
60,961
kWh
-
08 2.4221: Install compressor air intakes in coolest locations $1,830 $200 $1,830
32,239
kWh
-
09 2.4111: Utilize energy-efficient belts and other improved mechanisms $1,464 $1,800 $1,464
25,791
kWh
-
10 2.3132: Recharge batteries on during off-peak demand periods $1,145 $300 $1,145
-
kWh
-
11 2.7492: Use proper thickness of insulation on building envelope $768 $1,435 - $768
-
MMBtu
12 2.2136: Install / repair insulation on steam lines $454 $630 - $454
-
MMBtu
13 2.7444: Close holes and openings in building such as broken windows $183 $80 - $183
-
MMBtu
14 2.7142: Utilize higher efficiency lamps and/or ballasts $1,631 $2,970 $1,631
28,722
kWh
-
TOTAL RECOMMENDED $47,577 $21,515 $20,613
342,907
kWh
$26,964
-
MMBtu
TOTAL IMPLEMENTED $29,735 $6,300 $16,171
264,654
kWh
$13,564
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs