| Assessment Year | 1986 |
|---|---|
| Principal Product | VARIOS LENGTH/WIDTH BOARD |
| NAICS |
n/a
|
| SIC | 2421: Sawmills and Planing Mills, General |
| Sales Range | $10 M to 50M |
| # of Employees | 100 |
| Plant Area |
n/a
|
| Annual Production | 27,300
thousand feet
|
| Production Hrs. Annual | 4,160
hrs
|
| Location (State) | Colorado |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $196,888 | 2,805,100 |
kWh
|
$0.070 |
| Natural Gas | $10,504 | 4,734 |
MMBtu
|
$2.22 |
| Wood | $101,700 | 101,704 |
MMBtu
|
$1.00 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $78,669 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $63,415 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Wood Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.3414: Burn waste to produce steam to drive a steam turbine generator set and use steam exhaust for heat | $11,487 | $120,000 |
$16,220
291,325
kWh
|
- |
$(-4,733.0)
-
MMBtu
|
|
| 02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $10,038 | $4,650 |
$10,038
143,025
kWh
|
- | - | |
| 03 | 2.4312: Improve lubrication practices | $16,456 | - |
$16,456
234,467
kWh
|
- | - | |
| 04 | 2.2511: Insulate bare equipment | $1,724 | $2,000 |
$1,584
22,567
kWh
|
$140
-
MMBtu
|
- | |
| 05 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $31,018 | - |
$31,018
-
kWh
|
- | - | |
| 06 | 2.6212: Turn off equipment during breaks, reduce operating time | $1,296 | $400 |
$1,296
18,464
kWh
|
- | - | |
| 08 | 2.4221: Install compressor air intakes in coolest locations | $1,810 | - |
$1,810
25,791
kWh
|
- | - | |
| 09 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,571 | $500 |
$2,571
36,635
kWh
|
- | - | |
| 10 | 2.7261: Install timers and/or thermostats | $638 | $200 |
$638
9,086
kWh
|
- | - | |
| 11 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $1,405 | $1,000 |
$1,625
23,154
kWh
|
$(-220.0)
-
MMBtu
|
- | |
| 12 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $226 | $132 |
$226
3,224
kWh
|
- | - | |
| TOTAL RECOMMENDED | $78,669 | $128,882 |
$83,482
807,738
kWh
|
$(-80.0)
-
MMBtu
|
$(-4,733.0)
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $63,415 | $5,682 |
$63,415
461,606
kWh
|
- | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Wood Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs