Assessment Year | 1986 |
---|---|
Principal Product | HAM,BACON,SAUSAGE,WIENER |
NAICS |
n/a
|
SIC | 2013: Sausages and Other Prepared Meat Products |
Sales Range | $10 M to 50M |
# of Employees | 130 |
Plant Area |
n/a
|
Annual Production | 20,000,000
lb
|
Production Hrs. Annual | 2,340
hrs
|
Location (State) | Colorado |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $261,659 | 5,080,891 |
kWh
|
$0.051 |
Natural Gas | $167,067 | 40,713 |
MMBtu
|
$4.10 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $47,950 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $13,574 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.3191: Use demand controller or load shedder | $4,238 | $2,400 |
$4,238
-
kWh
|
- | |
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,887 | $2,400 |
$2,887
55,979
kWh
|
- | |
03 | 2.2523: Reduce infiltration to refrigerated areas; isolate hot equipment from refrigerated areas | $3,563 | $2,200 |
$3,563
69,168
kWh
|
- | |
04 | 2.2136: Install / repair insulation on steam lines | $1,266 | $828 |
$691
13,482
kWh
|
$575
-
MMBtu
|
|
05 | 2.1233: Analyze flue gas for proper air/fuel ratio | $5,899 | $300 | - |
$5,899
-
MMBtu
|
|
06 | 2.1222: Install turbulators | $4,253 | - | - |
$4,253
-
MMBtu
|
|
07 | 2.2511: Insulate bare equipment | $314 | $684 | - |
$314
-
MMBtu
|
|
08 | 2.2121: Increase amount of condensate returned | $150 | $80 | - |
$150
-
MMBtu
|
|
09 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,130 | $250 |
$1,130
21,981
kWh
|
- | |
10 | 2.4221: Install compressor air intakes in coolest locations | $290 | - |
$290
5,569
kWh
|
- | |
11 | 2.4312: Improve lubrication practices | $7,937 | - |
$7,937
154,162
kWh
|
- | |
12 | 2.7261: Install timers and/or thermostats | $661 | $79 |
$130
2,638
kWh
|
$531
-
MMBtu
|
|
13 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $905 | $1,206 |
$905
17,585
kWh
|
- | |
14 | 2.2425: Use flue gases to heat process or service water | $7,372 | $25,000 | - |
$7,372
-
MMBtu
|
|
15 | 2.2447: Heat water with exhaust heat | $7,085 | $25,000 | - |
$7,085
-
MMBtu
|
|
TOTAL RECOMMENDED | $47,950 | $60,427 |
$21,771
340,564
kWh
|
$26,179
-
MMBtu
|
||
TOTAL IMPLEMENTED | $13,574 | $4,943 |
$6,419
124,854
kWh
|
$7,155
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |