| Assessment Year | 1986 |
|---|---|
| Principal Product | HAM,BACON,SAUSAGE,WIENER |
| NAICS |
n/a
|
| SIC | 2013: Sausages and Other Prepared Meat Products |
| Sales Range | $10 M to 50M |
| # of Employees | 130 |
| Plant Area |
n/a
|
| Annual Production | 20,000,000
lb
|
| Production Hrs. Annual | 2,340
hrs
|
| Location (State) | Colorado |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $261,659 | 5,080,891 |
kWh
|
$0.051 |
| Natural Gas | $167,067 | 40,713 |
MMBtu
|
$4.10 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $47,950 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $13,574 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.3191: Use demand controller or load shedder | $4,238 | $2,400 |
$4,238
-
kWh
|
- | |
| 02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,887 | $2,400 |
$2,887
55,979
kWh
|
- | |
| 03 | 2.2523: Reduce infiltration to refrigerated areas; isolate hot equipment from refrigerated areas | $3,563 | $2,200 |
$3,563
69,168
kWh
|
- | |
| 04 | 2.2136: Install / repair insulation on steam lines | $1,266 | $828 |
$691
13,482
kWh
|
$575
-
MMBtu
|
|
| 05 | 2.1233: Analyze flue gas for proper air/fuel ratio | $5,899 | $300 | - |
$5,899
-
MMBtu
|
|
| 06 | 2.1222: Install turbulators | $4,253 | - | - |
$4,253
-
MMBtu
|
|
| 07 | 2.2511: Insulate bare equipment | $314 | $684 | - |
$314
-
MMBtu
|
|
| 08 | 2.2121: Increase amount of condensate returned | $150 | $80 | - |
$150
-
MMBtu
|
|
| 09 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,130 | $250 |
$1,130
21,981
kWh
|
- | |
| 10 | 2.4221: Install compressor air intakes in coolest locations | $290 | - |
$290
5,569
kWh
|
- | |
| 11 | 2.4312: Improve lubrication practices | $7,937 | - |
$7,937
154,162
kWh
|
- | |
| 12 | 2.7261: Install timers and/or thermostats | $661 | $79 |
$130
2,638
kWh
|
$531
-
MMBtu
|
|
| 13 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $905 | $1,206 |
$905
17,585
kWh
|
- | |
| 14 | 2.2425: Use flue gases to heat process or service water | $7,372 | $25,000 | - |
$7,372
-
MMBtu
|
|
| 15 | 2.2447: Heat water with exhaust heat | $7,085 | $25,000 | - |
$7,085
-
MMBtu
|
|
| TOTAL RECOMMENDED | $47,950 | $60,427 |
$21,771
340,564
kWh
|
$26,179
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $13,574 | $4,943 |
$6,419
124,854
kWh
|
$7,155
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs