ITAC Assessment: CO0048
ITAC logo
ITAC Assessment: CO0048
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1985
Principal Product SPORTING ACCESSORIES
NAICS
n/a
SIC 3949: Sporting and Athletic Goods, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 275
Plant Area
n/a
Annual Production 500,000
lb
Production Hrs. Annual 5,616
hrs
Location (State) Colorado

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $207,413 3,519,930
kWh
Natural Gas $106,875 22,668
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $74,304 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $49,532

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.7261: Install timers and/or thermostats $11,078 $47 $290
4,982
kWh
$10,788
-
MMBtu
02 2.7447: Install vinyl strip / high speed / air curtain doors $6,297 $400 - $6,297
-
MMBtu
03 2.2444: Use hot process fluids to preheat incoming process fluids $1,843 $25 - $1,843
-
MMBtu
04 2.7492: Use proper thickness of insulation on building envelope $541 $750 - $541
-
MMBtu
05 2.1233: Analyze flue gas for proper air/fuel ratio $128 $300 - $128
-
MMBtu
06 2.7243: Improve air circulation with destratification fans / other methods $14,121 $4,500 $(-447.0)
(-7,620)
kWh
$14,568
-
MMBtu
07 2.7447: Install vinyl strip / high speed / air curtain doors $554 $225 $15
293
kWh
$539
-
MMBtu
08 2.2428: Use flue gases in radiant heater for space heating, ovens, etc $10,651 $14,000 - $10,651
-
MMBtu
09 2.7111: Reduce illumination to minimum necessary levels $29,091 $2,343 $29,091
493,845
kWh
-
TOTAL RECOMMENDED $74,304 $22,590 $28,949
491,500
kWh
$45,355
-
MMBtu
TOTAL IMPLEMENTED $49,532 $4,090 $29,396
499,120
kWh
$20,136
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs