| Assessment Year | 1985 |
|---|---|
| Principal Product | MOBILE HOMES |
| NAICS |
n/a
|
| SIC | 2451: Mobile Homes |
| Sales Range | $5 M to 10M |
| # of Employees | 85 |
| Plant Area |
n/a
|
| Annual Production | 300
pieces
|
| Production Hrs. Annual | 2,210
hrs
|
| Location (State) | Colorado |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $25,390 | 366,940 |
kWh
|
$0.069 |
| Natural Gas | $21,151 | 4,473 |
MMBtu
|
$4.73 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $11,297 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $2,101 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $568 | $353 |
$568
8,206
kWh
|
- | |
| 02 | 2.7447: Install vinyl strip / high speed / air curtain doors | $1,533 | $3,200 | - |
$1,533
-
MMBtu
|
|
| 03 | 2.7233: Use properly designed and sized hvac equipment | $1,278 | $2,000 |
$1,278
18,464
kWh
|
- | |
| 04 | 2.7261: Install timers and/or thermostats | $4,121 | $218 |
$162
2,345
kWh
|
$3,959
-
MMBtu
|
|
| 05 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $2,572 | $4,000 |
$3,630
52,462
kWh
|
$(-1,058.0)
-
MMBtu
|
|
| 06 | 2.2437: Recover waste heat from equipment | $657 | $1,200 | - |
$657
-
MMBtu
|
|
| 07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $568 | $30 |
$568
8,206
kWh
|
- | |
| TOTAL RECOMMENDED | $11,297 | $11,001 |
$6,206
89,683
kWh
|
$5,091
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $2,101 | $3,553 |
$568
8,206
kWh
|
$1,533
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs