ITAC Assessment: CI0021
ITAC logo
ITAC Assessment: CI0021
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2023
Principal Product Plastic Pipes, Valves and Fittings
NAICS 332996: Fabricated Pipe and Pipe Fitting Manufacturing
SIC 3498: Fabricated Pipe and Pipe Fittings
Sales Range $100
M
to 500
M
# of Employees 120
Plant Area 110,000
ft2
Annual Production 1,000,000
pieces
Production Hrs. Annual 4,500
hrs
Location (State) California

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $84,846 661,183
kWh
Electricity Demand $87,807 4,877
kW-mo/yr
Natural Gas $4,025 221
MMBtu
Waste Disposal Costs
Water Usage $5,059 320
Tgal
Water Disposal $1,083 320
Tgal
TOTAL YEARLY COSTS $182,820
RECOMMENDED SAVINGS* $46,627 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings
01 2.7232: Replace existing hvac unit with high efficiency model $13,010 $43,210 $13,010
49,056
kWh
-
02 2.4224: Upgrade controls on compressors $10,578 $2,500 $5,743
44,760
kWh
$4,835
-
kW-mo/yr
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $7,619 $300 $4,671
36,405
kWh
$2,948
-
kW-mo/yr
04 2.7142: Utilize higher efficiency lamps and/or ballasts $4,563 $3,850 $3,321
25,884
kWh
$1,242
-
kW-mo/yr
05 2.7134: Use photocell controls $3,983 $2,500 $2,075
16,171
kWh
$1,908
-
kW-mo/yr
06 2.6218: Turn off equipment when not in use $3,548 - $3,548
27,652
kWh
-
07 2.7135: Install occupancy sensors $2,177 $2,500 $1,700
13,248
kWh
$477
-
kW-mo/yr
08 2.4239: Eliminate or reduce compressed air usage $1,149 $500 $1,149
8,952
kWh
-
TOTAL RECOMMENDED $46,627 $55,360 $35,217
222,128
kWh
$11,410
-
kW-mo/yr
TOTAL IMPLEMENTED - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs