| Assessment Year | 2019 |
|---|---|
| Principal Product | Corrugated Containers |
| NAICS | 322211: Corrugated and Solid Fiber Box Manufacturing |
| SIC | 2653: Corrugated and Solid Fiber Boxes |
| Sales Range | $50 M to 100M |
| # of Employees | 112 |
| Plant Area |
207,000
ft2
|
| Annual Production | 1,400,000
thousand feet
|
| Production Hrs. Annual | 4,992
hrs
|
| Location (State) | Idaho |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $410,867 | 7,591,200 |
kWh
|
$0.054 |
| Electricity Fees | $480 | - |
|
- |
| Natural Gas | $32,172 | 73,255 |
MMBtu
|
$0.44 |
| TOTAL YEARLY COSTS | $443,519 | |||
| RECOMMENDED SAVINGS* | $69,944 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $17,020 | $1,102 |
$17,020
314,484
kWh
|
- | |
| 02 | 2.4322: Use or replace with energy efficient substitutes | $4,961 | $6,744 |
$4,961
91,669
kWh
|
- | |
| 03 | 2.2414: Use waste heat from hot flue gases to preheat | $7,707 | $13,390 | - |
$7,707
-
MMBtu
|
|
| 04 | 2.4224: Upgrade controls on compressors | $6,885 | $10,080 |
$6,885
127,215
kWh
|
- | |
| 05 | 2.4133: Use most efficient type of electric motors | $18,337 | $34,309 |
$18,337
338,821
kWh
|
- | |
| 06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $3,874 | $4,056 |
$3,874
71,579
kWh
|
- | |
| 07 | 2.6231: Utilize controls to operate equipment only when needed | $7,558 | $22,950 |
$7,558
139,651
kWh
|
- | |
| 08 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,857 | $712 |
$1,857
34,316
kWh
|
- | |
| 09 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,745 | $450 |
$1,745
32,245
kWh
|
- | |
| TOTAL RECOMMENDED | $69,944 | $93,793 |
$62,237
1,149,980
kWh
|
$7,707
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs