| Assessment Year | 2013 |
|---|---|
| Principal Product | Lumber |
| NAICS | 321113: Sawmills |
| SIC | 2421: Sawmills and Planing Mills, General |
| Sales Range | $1 M to 5M |
| # of Employees | 160 |
| Plant Area |
352,939
ft2
|
| Annual Production | 250,000,000
thousand feet
|
| Production Hrs. Annual | 5,000
hrs
|
| Location (State) | Idaho |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $1,271,820 | 26,917,770 |
kWh
|
$0.047 |
| Electricity Demand | $228,756 | 57,580 |
kW-mo/yr
|
$3.97 |
| Wood | $528,450 | 1,004,063 |
MMBtu
|
$0.53 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $46,940 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $14,676 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Wood Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.6231: Utilize controls to operate equipment only when needed | $1,483 | $900 |
$1,483
31,417
kWh
|
- | - | |
| 02 | 2.6218: Turn off equipment when not in use | $3,601 | $8,272 |
$3,601
74,580
kWh
|
- | - | |
| 03 | 2.6212: Turn off equipment during breaks, reduce operating time | $5,998 | - |
$5,998
127,086
kWh
|
- | - | |
| 04 | 2.4226: Use / purchase optimum sized compressor | $2,065 | $8,525 |
$1,848
39,328
kWh
|
$217
-
kW-mo/yr
|
- | |
| 05 | 2.4237: Substitute compressed air cooling with water or air cooling | $11,249 | $3,500 |
$11,249
253,300
kWh
|
- | - | |
| 06 | 3.1161: Eliminate/reduce an operation | $1,098 | $422 |
$1,098
20,839
kWh
|
- | - | |
| 07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,594 | $26,100 |
$3,218
68,181
kWh
|
$376
-
kW-mo/yr
|
- | |
| 08 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $2,596 | $6,725 |
$2,324
49,248
kWh
|
$272
-
kW-mo/yr
|
- | |
| 09 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $14,916 | $14,075 |
$13,356
282,960
kWh
|
$1,560
-
kW-mo/yr
|
- | |
| 10 | 2.2511: Insulate bare equipment | $340 | $2,905 | - | - |
$340
-
MMBtu
|
|
| TOTAL RECOMMENDED | $46,940 | $71,423 |
$44,176
946,939
kWh
|
$2,424
-
kW-mo/yr
|
$340
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $14,676 | $35,272 |
$14,300
301,264
kWh
|
$376
-
kW-mo/yr
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Wood Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs