| Assessment Year | 1998 |
|---|---|
| Principal Product | Carbon dioxide generation equipment |
| NAICS |
n/a
|
| SIC | 3569: General Industrial Machinery and Equipment, Not Elsewhere |
| Sales Range | $10 M to 50M |
| # of Employees | 86 |
| Plant Area |
60,000
ft2
|
| Annual Production | 35
pieces
|
| Production Hrs. Annual | 2,600
hrs
|
| Location (State) | Florida |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $49,532 | 1,041,325 |
kWh
|
$0.048 |
| Electricity Demand | $28,005 | 3,444 |
kW-mo/yr
|
$8.13 |
| LPG | $7,419 | 628 |
MMBtu
|
$11.81 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $22,216 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $6,819 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $82 | $154 |
$40
879
kWh
|
$42
-
kW-mo/yr
|
- | |
| 02 | 2.7111: Reduce illumination to minimum necessary levels | $1,517 | $139 |
$951
19,930
kWh
|
$566
-
kW-mo/yr
|
- | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,836 | $7,316 |
$1,153
24,033
kWh
|
$683
-
kW-mo/yr
|
- | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,194 | $951 |
$690
14,361
kWh
|
$504
-
kW-mo/yr
|
- | |
| 05 | 2.7232: Replace existing hvac unit with high efficiency model | $660 | $1,896 |
$393
8,206
kWh
|
$267
-
kW-mo/yr
|
- | |
| 06 | 2.7135: Install occupancy sensors | $340 | $832 |
$340
23,447
kWh
|
- | - | |
| 07 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $144 | $400 |
$144
2,931
kWh
|
- | - | |
| 08 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $781 | $850 |
$781
10,551
kWh
|
- | - | |
| 09 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $9,559 | $9,000 | - | - | $9,559 | |
| 10 | 3.4111: Use closed cycle process to minimize waste water production | $2,468 | $7,000 | - | - | $2,468 | |
| 11 | 2.8121: Apply for tax-free status for energy purchases | $3,635 | $3,215 | - | - | $3,635 | |
| TOTAL RECOMMENDED | $22,216 | $31,753 |
$4,492
104,338
kWh
|
$2,062
-
kW-mo/yr
|
$15,662 | ||
| TOTAL IMPLEMENTED | $6,819 | $6,654 |
$2,309
42,497
kWh
|
$875
-
kW-mo/yr
|
$3,635 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs