Assessment Year | 2013 |
---|---|
Principal Product | Fruit snacks |
NAICS | 311919: Other Snack Food Manufacturing |
SIC | 2052: Cookies and Crackers |
Sales Range | $100 M to 500M |
# of Employees | 350 |
Plant Area |
256,750
ft2
|
Annual Production | 70,000,000
pieces
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,143,882 | 13,084,656 |
kWh
|
$0.087 |
Electricity Demand | $125,062 | 24,287 |
kW-mo/yr
|
$5.15 |
Electricity Fees | $17,614 | - |
|
- |
Natural Gas | $442,755 | 92,848 |
MMBtu
|
$4.77 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $137,249 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $46,982 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7447: Install vinyl strip / high speed / air curtain doors | $51,971 | $201,300 |
$51,971
613,599
kWh
|
- | - | - | - | |
02 | 2.4133: Use most efficient type of electric motors | $29,607 | $16,210 |
$27,396
313,458
kWh
|
$2,211
-
kW-mo/yr
|
- | - | - | |
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $14,355 | $25 |
$13,284
151,977
kWh
|
$1,071
-
kW-mo/yr
|
- | - | - | |
04 | 2.4221: Install compressor air intakes in coolest locations | $12,401 | $2,700 |
$11,475
131,287
kWh
|
$926
-
kW-mo/yr
|
- | - | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $8,527 | $8,640 |
$7,690
90,788
kWh
|
$640
-
kW-mo/yr
|
- | $197 | - | |
06 | 2.2414: Use waste heat from hot flue gases to preheat | $8,030 | $11,000 | - | - |
$8,030
-
MMBtu
|
- | - | |
07 | 2.7135: Install occupancy sensors | $7,685 | $2,257 |
$7,166
84,605
kWh
|
$519
-
kW-mo/yr
|
- | - | - | |
08 | 2.1222: Install turbulators | $3,136 | $3,000 | - | - |
$3,136
-
MMBtu
|
- | - | |
09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,163 | $1,660 |
$194
2,289
kWh
|
$141
-
kW-mo/yr
|
- | $346 | $482 | |
10 | 2.7134: Use photocell controls | $374 | $435 |
$236
3,168
kWh
|
$80
-
kW-mo/yr
|
- | $33 | $25 | |
TOTAL RECOMMENDED | $137,249 | $247,227 |
$119,412
1,391,171
kWh
|
$5,588
-
kW-mo/yr
|
$11,166
-
MMBtu
|
$576 | $507 | ||
TOTAL IMPLEMENTED | $46,982 | $28,767 |
$42,446
491,140
kWh
|
$3,511
-
kW-mo/yr
|
- | $543 | $482 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings |