ITAC Assessment: BD0263
ITAC logo
ITAC Assessment: BD0263
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2004
Principal Product Shelving Systems and Store Fixtures
NAICS 337215: Showcase, Partition, Shelving, and Locker Manufacturing
SIC 2541: Wood Office and Store Fixtures, Partitions, Shelving, and Lockers
Sales Range $10
M
to 50
M
# of Employees 116
Plant Area 155,000
ft2
Annual Production 10,000
pieces
Production Hrs. Annual 3,150
hrs
Location (State) Illinois

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $208,908 2,363,105
kWh
Electricity Demand $85,054 9,055
kW-mo/yr
Natural Gas $35,595 4,993
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $98,247 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $40,651

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Solid Waste (non-haz) Savings Personnel Changes Savings Primary Raw Material Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $29,300 $58,035 $11,838
273,399
kWh
$9,780
-
kW-mo/yr
- - $3,913 $3,769
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $12,939 $2,400 $8,647
199,691
kWh
$4,292
-
kW-mo/yr
- - - -
03 2.7231: Use radiant heater for spot heating $9,868 $20,520 $80
1,818
kWh
$196
-
kW-mo/yr
$9,592
-
MMBtu
- - -
04 2.2531: Re-size charging openings or add movable cover or door $9,390 $20,020 - - $2,630
-
MMBtu
- $6,760 -
05 2.4133: Use most efficient type of electric motors $1,226 $3,114 $756
17,471
kWh
$470
-
kW-mo/yr
- - - -
06 2.4221: Install compressor air intakes in coolest locations $2,501 $750 $1,370
31,631
kWh
$1,131
-
kW-mo/yr
- - - -
07 2.7135: Install occupancy sensors $1,654 $1,575 $600
13,853
kWh
$1,054
-
kW-mo/yr
- - - -
08 2.4239: Eliminate or reduce compressed air usage $1,537 $4,000 $409
9,457
kWh
$1,128
-
kW-mo/yr
- - - -
09 2.7444: Close holes and openings in building such as broken windows $691 $1,050 - - $691
-
MMBtu
- - -
10 2.7142: Utilize higher efficiency lamps and/or ballasts $421 $377 $187
4,328
kWh
$55
-
kW-mo/yr
- - $75 $104
11 3.5317: Sell / offer by-product as animal feed $26,600 $130 - - - $26,600
-
lb
- -
12 3.5315: Lease / purchase baler; sell cardboard to recycler $2,120 $260 - - - $2,120
-
lb
- -
TOTAL RECOMMENDED $98,247 $112,231 $23,887
551,648
kWh
$18,106
-
kW-mo/yr
$12,913
-
MMBtu
$28,720
-
lb
$10,748 $3,873
TOTAL IMPLEMENTED $40,651 $3,957 $8,834
204,019
kWh
$4,347
-
kW-mo/yr
$691
-
MMBtu
$26,600
-
lb
$75 $104
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Solid Waste (non-haz) Savings Personnel Changes Savings Primary Raw Material Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs