Assessment Year | 1995 |
---|---|
Principal Product | Pipe Fittings |
NAICS |
n/a
|
SIC | 3498: Fabricated Pipe and Pipe Fittings |
Sales Range | $5 M to 10M |
# of Employees | 70 |
Plant Area |
26,000
ft2
|
Annual Production | 0
lb
|
Production Hrs. Annual | 96,000
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $70,642 | 901,524 |
kWh
|
$0.078 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $22,641 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $19,707 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $19,345 | $11,900 |
$24,727
315,358
kWh
|
$(-5,382.0)
-
MMBtu
|
|
02 | 2.4133: Use most efficient type of electric motors | $1,483 | $3,900 |
$1,483
19,050
kWh
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $997 | $1,279 |
$997
12,603
kWh
|
- | |
04 | 2.7135: Install occupancy sensors | $362 | $300 |
$362
4,689
kWh
|
- | |
05 | 2.7111: Reduce illumination to minimum necessary levels | $112 | $100 |
$112
1,465
kWh
|
- | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $140 | $110 |
$140
1,758
kWh
|
- | |
07 | 2.4221: Install compressor air intakes in coolest locations | $202 | $200 |
$202
2,638
kWh
|
- | |
TOTAL RECOMMENDED | $22,641 | $17,789 |
$28,023
357,561
kWh
|
$(-5,382.0)
-
MMBtu
|
||
TOTAL IMPLEMENTED | $19,707 | $12,200 |
$25,089
320,047
kWh
|
$(-5,382.0)
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs