Assessment Year | 1995 |
---|---|
Principal Product | Steel Fabricators |
NAICS |
n/a
|
SIC | 3599: Industrial and Commercial Machinery and Equipment, Not Elsewhere Classified |
Sales Range | $1 M to 5M |
# of Employees | 35 |
Plant Area |
26,416
ft2
|
Annual Production | 833
ton
|
Production Hrs. Annual | 2,042
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $37,667 | 535,463 |
kWh
|
$0.070 |
Natural Gas | $4,558 | 892 |
MMBtu
|
$5.11 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $8,523 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $5,231 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Primary Raw Material Savings |
---|---|---|---|---|---|---|---|
01 | 2.7447: Install vinyl strip / high speed / air curtain doors | $29 | $126 | - |
$29
-
MMBtu
|
- | |
02 | 2.2531: Re-size charging openings or add movable cover or door | $1,170 | $2,100 | - |
$1,170
-
MMBtu
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $297 | $679 |
$297
4,103
kWh
|
- | - | |
04 | 2.7111: Reduce illumination to minimum necessary levels | $1,326 | $135 |
$1,326
18,757
kWh
|
- | - | |
05 | 2.7135: Install occupancy sensors | $182 | $350 |
$182
2,638
kWh
|
- | - | |
06 | 2.4221: Install compressor air intakes in coolest locations | $1,244 | $200 |
$1,244
17,585
kWh
|
- | - | |
07 | 2.4322: Use or replace with energy efficient substitutes | $288 | $700 | - | - | $288 | |
08 | 2.4133: Use most efficient type of electric motors | $3,987 | $4,500 |
$3,987
56,565
kWh
|
- | - | |
TOTAL RECOMMENDED | $8,523 | $8,790 |
$7,036
99,648
kWh
|
$1,199
-
MMBtu
|
$288 | ||
TOTAL IMPLEMENTED | $5,231 | $4,700 |
$5,231
74,150
kWh
|
- | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Primary Raw Material Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs