Assessment Year | 1988 |
---|---|
Principal Product | DAIRY PRODUCTS |
NAICS |
n/a
|
SIC | 2026: Fluid Milk |
Sales Range | $10 M to 50M |
# of Employees | 105 |
Plant Area |
n/a
|
Annual Production | 18,000
Tgal
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | North Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $546,969 | 10,245,604 |
kWh
|
$0.053 |
Natural Gas | $185,073 | 50,669 |
MMBtu
|
$3.65 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $26,140 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,981 | $2,213 |
$2,981
55,686
kWh
|
- | - | |
02 | 2.4133: Use most efficient type of electric motors | $2,740 | $2,305 |
$2,740
51,290
kWh
|
- | - | |
03 | 2.1233: Analyze flue gas for proper air/fuel ratio | $6,223 | - | - |
$6,423
-
MMBtu
|
$(-200.0) | |
04 | 2.4312: Improve lubrication practices | $509 | - |
$509
9,672
kWh
|
- | - | |
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,707 | - |
$2,707
50,703
kWh
|
- | - | |
06 | 2.7226: Use computer programs to optimize hvac performance | $4,298 | $10,770 |
$4,298
80,598
kWh
|
- | - | |
07 | 2.4221: Install compressor air intakes in coolest locations | $845 | $1,160 |
$845
15,826
kWh
|
- | - | |
08 | 2.2511: Insulate bare equipment | $1,315 | $1,690 |
$1,315
24,619
kWh
|
- | - | |
09 | 2.7261: Install timers and/or thermostats | $1,847 | $670 |
$1,847
34,584
kWh
|
- | - | |
10 | 2.2121: Increase amount of condensate returned | $2,675 | $1,345 | - |
$2,675
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $26,140 | $20,153 |
$17,242
322,978
kWh
|
$9,098
-
MMBtu
|
$(-200.0) | ||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs