Assessment Year | 1987 |
---|---|
Principal Product | GRAY IRON CASTINGS |
NAICS |
n/a
|
SIC | 3321: Gray and Ductile Iron Foundries |
Sales Range | $1 M to 5M |
# of Employees | 37 |
Plant Area |
n/a
|
Annual Production | 600
ton
|
Production Hrs. Annual | 2,025
hrs
|
Location (State) | North Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $165,688 | 2,118,113 |
kWh
|
$0.078 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $3,780 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,780 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.6232: Install set-back timers | $538 | $485 |
$538
6,741
kWh
|
|
02 | 2.4133: Use most efficient type of electric motors | $231 | $303 |
$231
2,931
kWh
|
|
03 | 2.6212: Turn off equipment during breaks, reduce operating time | $954 | - |
$954
12,309
kWh
|
|
04 | 2.4312: Improve lubrication practices | $513 | - |
$513
6,448
kWh
|
|
05 | 2.4221: Install compressor air intakes in coolest locations | $83 | $150 |
$83
1,172
kWh
|
|
06 | 2.2491: Use cooling air which cools hot work pieces for space heating | $1,461 | $4,000 |
$1,461
18,757
kWh
|
|
TOTAL RECOMMENDED | $3,780 | $4,938 |
$3,780
48,358
kWh
|
||
TOTAL IMPLEMENTED | $3,780 | $4,938 |
$3,780
48,358
kWh
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs