Assessment Year 1987
Principal Product GRAY IRON CASTINGS
NAICS
n/a
SIC 3321: Gray and Ductile Iron Foundries
Sales Range $1
M
to 5
M
# of Employees 37
Plant Area
n/a
Annual Production 600
ton
Production Hrs. Annual 2,025
hrs
Location (State) North Carolina

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $165,688 2,118,113
kWh
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $3,780 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $3,780

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings
01 2.6232: Install set-back timers $538 $485 $538
6,741
kWh
02 2.4133: Use most efficient type of electric motors $231 $303 $231
2,931
kWh
03 2.6212: Turn off equipment during breaks, reduce operating time $954 - $954
12,309
kWh
04 2.4312: Improve lubrication practices $513 - $513
6,448
kWh
05 2.4221: Install compressor air intakes in coolest locations $83 $150 $83
1,172
kWh
06 2.2491: Use cooling air which cools hot work pieces for space heating $1,461 $4,000 $1,461
18,757
kWh
TOTAL RECOMMENDED $3,780 $4,938 $3,780
48,358
kWh
TOTAL IMPLEMENTED $3,780 $4,938 $3,780
48,358
kWh
Yearly Savings* Imp'd Cost* Electricity Usage Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs