Assessment Year | 1986 |
---|---|
Principal Product | ELECTRICAL CONNECTORS |
NAICS |
n/a
|
SIC | 3643: Current-Carrying Wiring Devices |
Sales Range | $50 M to 100M |
# of Employees | 300 |
Plant Area |
n/a
|
Annual Production | 50,000,000
pieces
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | North Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $153,145 | 3,022,274 |
kWh
|
$0.051 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $25,939 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $276 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.2437: Recover waste heat from equipment | $1,094 | $300 |
$1,094
21,395
kWh
|
|
02 | 2.7226: Use computer programs to optimize hvac performance | $19,039 | $10,350 |
$19,039
374,560
kWh
|
|
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,054 | $1,661 |
$4,054
80,012
kWh
|
|
04 | 2.4221: Install compressor air intakes in coolest locations | $1,415 | $250 |
$1,415
27,843
kWh
|
|
05 | 2.7261: Install timers and/or thermostats | $276 | $275 |
$276
5,569
kWh
|
|
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $61 | $90 |
$61
1,172
kWh
|
|
TOTAL RECOMMENDED | $25,939 | $12,926 |
$25,939
510,551
kWh
|
||
TOTAL IMPLEMENTED | $276 | $275 |
$276
5,569
kWh
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs