Assessment Year | 1985 |
---|---|
Principal Product | GREY & DUCT IRON CASTING |
NAICS |
n/a
|
SIC | 3322: Malleable Iron Foundries |
Sales Range | $5 M to 10M |
# of Employees | 27 |
Plant Area |
n/a
|
Annual Production | 0
units
|
Production Hrs. Annual | 4,000
hrs
|
Location (State) | North Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $185,950 | 3,065,944 |
kWh
|
$0.061 |
Natural Gas | $37,948 | 6,041 |
MMBtu
|
$6.28 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $9,417 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $258 | $192 |
$258
4,396
kWh
|
- | |
02 | 2.7447: Install vinyl strip / high speed / air curtain doors | $5,799 | $4,500 | - |
$5,799
-
MMBtu
|
|
03 | 2.6232: Install set-back timers | $3,360 | - |
$3,360
55,393
kWh
|
- | |
TOTAL RECOMMENDED | $9,417 | $4,692 |
$3,618
59,789
kWh
|
$5,799
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs