Assessment Year | 2024 |
---|---|
Principal Product | Canned foods |
NAICS | 311421: Fruit and Vegetable Canning |
SIC | 2033: Canned Fruits, Vegetables, Preserves, Jams, and Jellies |
Sales Range | $50 M to 100M |
# of Employees | 210 |
Plant Area |
512,378
ft2
|
Annual Production | 7,000,000
units
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Arizona |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $791,943 | 12,224,268 |
kWh
|
$0.065 | |
Electricity Demand | $544,587 | 28,614 |
kW-mo/yr
|
$19.03 | |
Electricity Fees | $283,135 | - |
|
- | |
Natural Gas | $1,232,702 | 400,793 |
MMBtu
|
$3.08 | |
Waste Disposal Costs | |||||
Water Usage | $605,855 | 98,285 |
Tgal
|
$6.16 | |
Water Disposal | $800,388 | 70,809 |
Tgal
|
$11.30 | |
TOTAL YEARLY COSTS | $4,258,610 | ||||
RECOMMENDED SAVINGS* | $549,502 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.9114: Use solar heat to make electricty | $242,289 | $2,885,843 |
$213,386
3,292,993
kWh
|
$28,903
-
kW-mo/yr
|
- | - | |
02 | 2.6231: Utilize controls to operate equipment only when needed | $165,792 | $921,043 |
$118,820
1,833,640
kWh
|
$46,972
-
kW-mo/yr
|
- | - | |
03 | 2.2414: Use waste heat from hot flue gases to preheat | $51,679 | $30,000 | - | - |
$51,679
-
MMBtu
|
- | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $43,824 | $34,114 |
$25,905
399,782
kWh
|
$10,249
-
kW-mo/yr
|
- | $7,670 | |
05 | 2.4224: Upgrade controls on compressors | $20,991 | $20,000 |
$15,042
232,128
kWh
|
$5,949
-
kW-mo/yr
|
- | - | |
06 | 4.611: Begin a practice of predictive / preventative maintenance | $14,086 | $15,866 |
$14,086
217,377
kWh
|
- | - | - | |
07 | 2.7226: Use computer programs to optimize hvac performance | $9,172 | $2,798 |
$6,573
101,439
kWh
|
$2,599
-
kW-mo/yr
|
- | - | |
08 | 2.7135: Install occupancy sensors | $1,281 | $406 |
$920
14,199
kWh
|
$361
-
kW-mo/yr
|
- | - | |
09 | 2.7132: Install timers on light switches in little used areas | $388 | $1,579 |
$278
4,294
kWh
|
$110
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $549,502 | $3,911,649 |
$395,010
6,095,852
kWh
|
$95,143
-
kW-mo/yr
|
$51,679
-
MMBtu
|
$7,670 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs