ITAC Assessment: CM1035
ITAC logo
ITAC Assessment: CM1035
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2024
Principal Product Small Arms and Ammunition
NAICS 332994: Small Arms, Ordnance, and Ordnance Accessories Manufacturing
SIC 3484: Small Arms
Sales Range $10
M
to 50
M
# of Employees 180
Plant Area 97,350
ft2
Annual Production 90,000
units
Production Hrs. Annual 6,032
hrs
Location (State) Colorado

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $155,245 3,596,115
kWh
Electricity Demand $189,254 9,869
kW-mo/yr
Electricity Fees $36,257 -
Natural Gas $34,882 5,298
MMBtu
TOTAL YEARLY COSTS $415,637
RECOMMENDED SAVINGS* $225,607 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Administrative Changes Savings Ancillary Material Cost Savings
01 2.9114: Use solar heat to make electricty $116,451 $1,482,720 $110,121
2,550,857
kWh
$6,330
-
kW-mo/yr
- - -
02 2.8227: Adjust / maintain fork lift trucks for most efficient operation $8,641 $34,268 $321
7,428
kWh
- - $8,320 -
03 2.7226: Use computer programs to optimize hvac performance $324 $330 $324
7,502
kWh
- - - -
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $526 $124 $279
6,462
kWh
$247
-
kW-mo/yr
- - -
05 2.7135: Install occupancy sensors $180 $141 $56
1,294
kWh
$124
-
kW-mo/yr
- - -
06 2.7491: Insulate glazing, walls, ceilings, and roofs $2,208 $1,271 - - $2,208
-
MMBtu
- -
07 2.3131: Reschedule plant operations or reduce load to avoid peaks $61,867 $29,430 - $61,867
-
kW-mo/yr
- - -
08 2.8121: Apply for tax-free status for energy purchases $1,605 - - - - $1,605 -
09 3.5146: Utilize a central coolant system for cleaning and reuse of metal working fluid $33,805 $102,000 $(-844.6)
(-19,550)
kWh
- - - $34,650
TOTAL RECOMMENDED $225,607 $1,650,284 $110,256
2,553,993
kWh
$68,568
-
kW-mo/yr
$2,208
-
MMBtu
$9,925 $34,650
TOTAL IMPLEMENTED - - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Administrative Changes Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs