| Assessment Year | 2022 |
|---|---|
| Principal Product | Recycled Plastic Products |
| NAICS | 326199: All Other Plastics Product Manufacturing |
| SIC | 3089: Plastics Products, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 120 |
| Plant Area |
153,969
ft2
|
| Annual Production | 12,300,000
units
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | Arizona |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $1,450,061 | 30,838,665 |
kWh
|
$0.047 |
| Electricity Demand | $785,019 | 86,611 |
kW-mo/yr
|
$9.06 |
| Electricity Fees | $110,243 | - |
|
- |
| TOTAL YEARLY COSTS | $2,345,323 | |||
| RECOMMENDED SAVINGS* | $92,731 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Other Liquid (haz) Savings | Ancillary Material Cost Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.4324: Replace hydraulic / pneumatic equipment with electric equipment | $29,267 | $226,584 |
$(-18,733.0)
(-398,571)
kWh
|
- |
$36,000
-
gal
|
- | $12,000 | |
| 02 | 2.4221: Install compressor air intakes in coolest locations | $22,746 | $3,707 |
$17,987
382,701
kWh
|
$4,759
-
kW-mo/yr
|
- | - | - | |
| 03 | 2.7261: Install timers and/or thermostats | $21,371 | $9,286 |
$19,622
417,498
kWh
|
$1,749
-
kW-mo/yr
|
- | - | - | |
| 04 | 2.7228: Avoid introducing hot, humid, or dirty air into hvac system | $16,536 | $3,537 |
$11,560
245,943
kWh
|
$4,976
-
kW-mo/yr
|
- | - | - | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,420 | $3,762 |
$1,240
26,419
kWh
|
$504
-
kW-mo/yr
|
- | $676 | - | |
| 06 | 2.3135: Schedule routine maintenance during non-operating periods | $391 | $1,619 | - |
$391
-
kW-mo/yr
|
- | - | - | |
| TOTAL RECOMMENDED | $92,731 | $248,495 |
$31,676
673,990
kWh
|
$12,379
-
kW-mo/yr
|
$36,000
-
gal
|
$676 | $12,000 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Other Liquid (haz) Savings | Ancillary Material Cost Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs