Assessment Year | 2022 |
---|---|
Principal Product | Archery Equipment |
NAICS | 339920: Sporting and Athletic Goods Manufacturing |
SIC | 3949: Sporting and Athletic Goods, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 198 |
Plant Area |
78,600
ft2
|
Annual Production | 33,000
units
|
Production Hrs. Annual | 8,640
hrs
|
Location (State) | Arizona |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $170,999 | 3,457,616 |
kWh
|
$0.049 | |
Electricity Demand | $147,734 | 7,690 |
kW-mo/yr
|
$19.21 | |
Electricity Fees | $63,906 | - |
|
- | |
Waste Disposal Costs | |||||
Water Usage | $20,458 | 1,993 |
Tgal
|
$10.27 | |
TOTAL YEARLY COSTS | $403,097 | ||||
RECOMMENDED SAVINGS* | $181,278 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | One-time Revenue or Avoided Cost Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|
01 | 4.111: Add equipment/ operators to reduce production bottleneck | $138,858 | $8,368 |
$40,548
819,159
kWh
|
$(-1,690.0)
-
kW-mo/yr
|
- | $100,000 | |
02 | 2.9114: Use solar heat to make electricty | $10,545 | $141,340 |
$7,092
155,157
kWh
|
$3,453
-
kW-mo/yr
|
- | - | |
03 | 2.4222: Install adequate dryers on air lines to eliminate blowdown | $9,435 | $4,628 |
$5,535
111,824
kWh
|
$3,900
-
kW-mo/yr
|
- | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $9,222 | $8,635 |
$3,082
62,249
kWh
|
$5,934
-
kW-mo/yr
|
$206 | - | |
05 | 2.7263: Lower compressor pressure through a/c system modification | $7,266 | $30,762 |
$4,748
95,920
kWh
|
$2,518
-
kW-mo/yr
|
- | - | |
06 | 2.4224: Upgrade controls on compressors | $3,883 | $1,160 |
$2,058
41,580
kWh
|
$1,825
-
kW-mo/yr
|
- | - | |
07 | 2.4239: Eliminate or reduce compressed air usage | $799 | $1,584 |
$431
8,699
kWh
|
$368
-
kW-mo/yr
|
- | - | |
08 | 2.7135: Install occupancy sensors | $772 | $59 |
$503
10,165
kWh
|
$269
-
kW-mo/yr
|
- | - | |
09 | 2.7135: Install occupancy sensors | $498 | $216 |
$498
10,056
kWh
|
- | - | - | |
TOTAL RECOMMENDED | $181,278 | $196,752 |
$64,495
1,314,809
kWh
|
$16,577
-
kW-mo/yr
|
$206 | $100,000 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | One-time Revenue or Avoided Cost Savings | Primary Product Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs