ITAC Assessment: AS0499
ITAC logo
ITAC Assessment: AS0499
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2021
Principal Product Nonwoven Textiles
NAICS 313230: Nonwoven Fabric Mills
SIC 2297: Non-woven Fabrics
Sales Range less than $500
k
# of Employees 20
Plant Area 150,000
ft2
Annual Production 51,000,000
lb
Production Hrs. Annual 4,769
hrs
Location (State) Arizona

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $90,964 1,217,904
kWh
Electricity Demand $30,290 3,533
kW-mo/yr
Electricity Fees $7,220 -
TOTAL YEARLY COSTS $128,474
RECOMMENDED SAVINGS* $16,992 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $4,289

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings One-time Revenue or Avoided Cost Savings
01 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $10,180 $1,532 $8,797
117,296
kWh
$1,383
-
kW-mo/yr
-
02 2.7142: Utilize higher efficiency lamps and/or ballasts $3,118 $6,351 $2,804
37,384
kWh
$450
-
kW-mo/yr
$(-136.0)
03 2.4239: Eliminate or reduce compressed air usage $1,171 $63 $916
12,216
kWh
$255
-
kW-mo/yr
-
04 2.4224: Upgrade controls on compressors $848 $607 $722
9,626
kWh
$126
-
kW-mo/yr
-
05 2.6231: Utilize controls to operate equipment only when needed $845 $2,880 $722
9,630
kWh
$123
-
kW-mo/yr
-
06 2.4111: Utilize energy-efficient belts and other improved mechanisms $624 $2,534 $389
5,176
kWh
$235
-
kW-mo/yr
-
07 2.7135: Install occupancy sensors $109 $394 $109
1,455
kWh
- -
08 2.6211: Conserve energy by efficient use of vending machines $97 $80 $48
643
kWh
$49
-
kW-mo/yr
-
TOTAL RECOMMENDED $16,992 $14,441 $14,507
193,426
kWh
$2,621
-
kW-mo/yr
$(-136.0)
TOTAL IMPLEMENTED $4,289 $6,414 $3,720
49,600
kWh
$705
-
kW-mo/yr
$(-136.0)
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs