Assessment Year | 1996 |
---|---|
Principal Product | Concrete Pipe |
NAICS |
n/a
|
SIC | 3272: Concrete Products, Except Block and Brick |
Sales Range | $10 M to 50M |
# of Employees | 100 |
Plant Area |
1,800,000
ft2
|
Annual Production | 0
units
|
Production Hrs. Annual | 3,000
hrs
|
Location (State) | Arizona |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $259,892 | 3,305,686 |
kWh
|
$0.079 |
Electricity Demand | $22,594 | 11,532 |
kW-mo/yr
|
$1.96 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $36,347 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $15,322 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Other Liquid (haz) Savings | Solid Waste (non-haz) Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7232: Replace existing hvac unit with high efficiency model | $1,786 | $2,100 |
$1,512
33,998
kWh
|
$274
-
kW-mo/yr
|
- | - | - | |
02 | 2.7261: Install timers and/or thermostats | $457 | $960 |
$457
9,672
kWh
|
- | - | - | - | |
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,267 | - |
$1,079
22,860
kWh
|
$188
-
kW-mo/yr
|
- | - | - | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,678 | $420 |
$3,056
64,771
kWh
|
$622
-
kW-mo/yr
|
- | - | - | |
05 | 2.4314: Use synthetic lubricant | $3,607 | $1,677 |
$2,900
61,547
kWh
|
$529
-
kW-mo/yr
|
$24
-
gal
|
- | $154 | |
06 | 2.4226: Use / purchase optimum sized compressor | $18,782 | - |
$16,234
344,373
kWh
|
$2,548
-
kW-mo/yr
|
- | - | - | |
07 | 2.4133: Use most efficient type of electric motors | $5,193 | $9,357 |
$4,402
93,494
kWh
|
$791
-
kW-mo/yr
|
- | - | - | |
08 | 2.7135: Install occupancy sensors | $1,427 | $3,300 |
$1,427
30,481
kWh
|
- | - | - | - | |
09 | 3.5316: Contract a wood pallet recycling company | $150 | - | - | - | - |
$150
-
lb
|
- | |
TOTAL RECOMMENDED | $36,347 | $17,814 |
$31,067
661,196
kWh
|
$4,952
-
kW-mo/yr
|
$24
-
gal
|
$150
-
lb
|
$154 | ||
TOTAL IMPLEMENTED | $15,322 | $14,754 |
$12,864
273,153
kWh
|
$2,130
-
kW-mo/yr
|
$24
-
gal
|
$150
-
lb
|
$154 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Other Liquid (haz) Savings | Solid Waste (non-haz) Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs