ITAC Assessment: AS0158
ITAC logo
ITAC Assessment: AS0158
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1995
Principal Product HVAC Metal Air Diffusers
NAICS
n/a
SIC 3444: Sheet Metal Work
Sales Range $10
M
to 50
M
# of Employees 450
Plant Area 200,000
ft2
Annual Production 2,500,000
pieces
Production Hrs. Annual 6,000
hrs
Location (State) Arizona

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $440,895 4,672,040
kWh
Natural Gas $150,681 28,833
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $105,377 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $19,900

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Administrative Changes Savings
01 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $19,900 $2,900 $19,900
218,933
kWh
-
02 2.4314: Use synthetic lubricant $4,212 $2,834 $4,212
40,739
kWh
-
03 2.4221: Install compressor air intakes in coolest locations $855 $200 $855
9,379
kWh
-
04 2.4133: Use most efficient type of electric motors $14,243 $9,227 $14,243
152,696
kWh
-
05 2.4111: Utilize energy-efficient belts and other improved mechanisms $4,179 - $4,179
44,256
kWh
-
06 2.7232: Replace existing hvac unit with high efficiency model $6,112 $18,838 $6,112
63,306
kWh
-
07 2.7261: Install timers and/or thermostats $784 $1,250 $784
9,965
kWh
-
08 2.7142: Utilize higher efficiency lamps and/or ballasts $24,992 $53,617 $24,992
269,343
kWh
-
09 2.7142: Utilize higher efficiency lamps and/or ballasts $1,155 $1,511 $1,155
12,603
kWh
-
10 2.7135: Install occupancy sensors $1,139 $825 $1,139
14,654
kWh
-
11 2.7142: Utilize higher efficiency lamps and/or ballasts $462 $499 $462
4,689
kWh
-
12 2.8114: Change rate schedules or other changes in utility service $27,344 $50,250 - $27,344
TOTAL RECOMMENDED $105,377 $141,951 $78,033
840,563
kWh
$27,344
TOTAL IMPLEMENTED $19,900 $2,900 $19,900
218,933
kWh
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs