Assessment Year | 1995 |
---|---|
Principal Product | Speaker Cabinets |
NAICS |
n/a
|
SIC | 3651: Household Audio and Video Equipment |
Sales Range | $100 M to 500M |
# of Employees | 58 |
Plant Area |
65,000
ft2
|
Annual Production | 2,400,000
pieces
|
Production Hrs. Annual | 7,344
hrs
|
Location (State) | Arizona |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $137,682 | 1,743,259 |
kWh
|
$0.079 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $18,151 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.4221: Install compressor air intakes in coolest locations | $840 | $250 |
$840
12,016
kWh
|
|
02 | 2.7423: Reduce heat gain by window tinting | $5,891 | $6,750 |
$5,891
104,045
kWh
|
|
03 | 2.7261: Install timers and/or thermostats | $1,241 | $1,500 |
$1,241
21,981
kWh
|
|
04 | 2.4133: Use most efficient type of electric motors | $5,626 | $4,409 |
$5,626
74,443
kWh
|
|
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,155 | - |
$2,155
29,601
kWh
|
|
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $983 | $979 |
$983
14,068
kWh
|
|
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,191 | $2,573 |
$1,191
16,999
kWh
|
|
08 | 2.7135: Install occupancy sensors | $224 | $510 |
$224
4,103
kWh
|
|
TOTAL RECOMMENDED | $18,151 | $16,971 |
$18,151
277,256
kWh
|
||
TOTAL IMPLEMENTED | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs