Assessment Year | 1993 |
---|---|
Principal Product | PREC MECHANICAL PRODUCTS |
NAICS |
n/a
|
SIC | 3599: Industrial and Commercial Machinery and Equipment, Not Elsewhere Classified |
Sales Range | $1 M to 5M |
# of Employees | 50 |
Plant Area |
n/a
|
Annual Production | 250,000
pieces
|
Production Hrs. Annual | 3,380
hrs
|
Location (State) | Arizona |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $75,383 | 788,394 |
kWh
|
$0.096 |
Natural Gas | $1,383 | 205 |
MMBtu
|
$6.75 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $8,109 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,034 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.4221: Install compressor air intakes in coolest locations | $163 | $200 |
$163
1,758
kWh
|
- | - | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $432 | $200 |
$432
4,396
kWh
|
- | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $773 | $506 |
$823
8,499
kWh
|
- | $(-50.0) | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $614 | $161 |
$614
6,448
kWh
|
- | - | |
05 | 2.7135: Install occupancy sensors | $1,003 | $603 |
$1,003
10,551
kWh
|
- | - | |
06 | 2.7233: Use properly designed and sized hvac equipment | $1,567 | $1,320 |
$1,567
16,413
kWh
|
- | - | |
07 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $191 | $1,072 |
$191
2,052
kWh
|
- | - | |
08 | 2.2614: Use cooling tower or economizer to replace chiller cooling | $2,540 | $7,500 |
$2,540
26,671
kWh
|
- | - | |
09 | 2.2511: Insulate bare equipment | $123 | $279 |
$123
1,172
kWh
|
- | - | |
10 | 2.7444: Close holes and openings in building such as broken windows | $703 | $500 |
$531
5,569
kWh
|
$172
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $8,109 | $12,341 |
$7,987
83,529
kWh
|
$172
-
MMBtu
|
$(-50.0) | ||
TOTAL IMPLEMENTED | $3,034 | $2,088 |
$2,912
30,187
kWh
|
$172
-
MMBtu
|
$(-50.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs