Assessment Year | 1992 |
---|---|
Principal Product | FLOUR TORTILLAS |
NAICS |
n/a
|
SIC | 2099: Food Preparations, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 200 |
Plant Area |
n/a
|
Annual Production | 29,000,000
lb
|
Production Hrs. Annual | 7,488
hrs
|
Location (State) | Arizona |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $185,308 | 2,961,899 |
kWh
|
$0.063 |
Natural Gas | $140,953 | 31,998 |
MMBtu
|
$4.41 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $16,289 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.3415: Use a fossil fuel engine to cogenerate electricity or motive power; and utilize heat | $3,687 | $91,000 |
$23,428
374,267
kWh
|
$(-14,127.0)
-
MMBtu
|
$(-5,614.0) | |
02 | 2.7226: Use computer programs to optimize hvac performance | $3,884 | $4,112 |
$3,884
62,134
kWh
|
- | - | |
03 | 2.7422: Plant trees or shrubs near windows to shield from sunlight | $326 | $600 |
$326
5,275
kWh
|
- | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,371 | $2,875 |
$1,371
21,981
kWh
|
- | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $273 | $5,904 |
$325
5,275
kWh
|
- | $(-52.0) | |
06 | 2.6232: Install set-back timers | $486 | $750 |
$486
7,913
kWh
|
- | - | |
07 | 2.7133: Use separate switches on perimeter lighting which may be turned off when natural light is available | $4,703 | $700 |
$4,703
75,029
kWh
|
- | - | |
08 | 2.4133: Use most efficient type of electric motors | $442 | $2,036 |
$442
7,034
kWh
|
- | - | |
09 | 2.4221: Install compressor air intakes in coolest locations | $638 | $300 |
$638
10,258
kWh
|
- | - | |
10 | 2.4312: Improve lubrication practices | $479 | $546 |
$479
7,620
kWh
|
- | - | |
TOTAL RECOMMENDED | $16,289 | $108,823 |
$36,082
576,786
kWh
|
$(-14,127.0)
-
MMBtu
|
$(-5,666.0) | ||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs