Assessment Year | 1992 |
---|---|
Principal Product | MODULAR OFFICE BUILDINGS |
NAICS |
n/a
|
SIC | 2451: Mobile Homes |
Sales Range | $10 M to 50M |
# of Employees | 100 |
Plant Area |
n/a
|
Annual Production | 250
pieces
|
Production Hrs. Annual | 2,340
hrs
|
Location (State) | Arizona |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $17,807 | 211,606 |
kWh
|
$0.084 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $5,075 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $4,923 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $264 | $2,663 |
$364
4,396
kWh
|
$(-100.0) | |
02 | 2.7261: Install timers and/or thermostats | $458 | $150 |
$458
5,569
kWh
|
- | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,834 | $500 |
$3,834
45,721
kWh
|
- | |
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $247 | - |
$247
2,931
kWh
|
- | |
05 | 2.4312: Improve lubrication practices | $152 | - |
$152
1,758
kWh
|
- | |
06 | 2.4221: Install compressor air intakes in coolest locations | $120 | $100 |
$120
1,465
kWh
|
- | |
TOTAL RECOMMENDED | $5,075 | $3,413 |
$5,175
61,840
kWh
|
$(-100.0) | ||
TOTAL IMPLEMENTED | $4,923 | $3,413 |
$5,023
60,082
kWh
|
$(-100.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs