Assessment Year | 1998 |
---|---|
Principal Product | Upholstered Furniture |
NAICS |
n/a
|
SIC | 2512: Wood Household Furniture, Upholstered |
Sales Range | $10 M to 50M |
# of Employees | 315 |
Plant Area |
230,050
ft2
|
Annual Production | 50,000
pieces
|
Production Hrs. Annual | 2,000
hrs
|
Location (State) | Arkansas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $107,010 | 2,209,848 |
kWh
|
$0.048 |
Electricity Demand | $85,943 | 9,135 |
kW-mo/yr
|
$9.41 |
Natural Gas | $21,461 | 3,978 |
MMBtu
|
$5.39 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $62,142 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $59,659 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $5,835 | $710 |
$2,483
56,565
kWh
|
$3,352
-
kW-mo/yr
|
- | - | - | - | |
02 | 2.4221: Install compressor air intakes in coolest locations | $871 | $412 |
$469
8,206
kWh
|
$402
-
kW-mo/yr
|
- | - | - | - | |
03 | 2.4133: Use most efficient type of electric motors | $439 | $793 |
$103
3,224
kWh
|
$336
-
kW-mo/yr
|
- | - | - | - | |
04 | 3.4115: Recover and reuse cooling water | $1,612 | $5,100 |
$(-219.0)
(-2,931)
kWh
|
$(-68.0)
-
kW-mo/yr
|
$1,899
-
Tgal
|
- | - | - | |
05 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $3,785 | - |
$(-81.0)
(-1,172)
kWh
|
$(-54.0)
-
kW-mo/yr
|
- |
$5,520
-
lb
|
$(-1,600.0) | - | |
06 | 4.441: Install automatic packing equipment | $11,200 | $3,665 | - | - | - | - | - | $11,200 | |
07 | 4.442: Install magazines for temporary storage | $38,400 | $7,000 | - | - | - | - | - | $38,400 | |
TOTAL RECOMMENDED | $62,142 | $17,680 |
$2,755
63,892
kWh
|
$3,968
-
kW-mo/yr
|
$1,899
-
Tgal
|
$5,520
-
lb
|
$(-1,600.0) | $49,600 | ||
TOTAL IMPLEMENTED | $59,659 | $12,168 |
$2,505
58,617
kWh
|
$3,634
-
kW-mo/yr
|
- |
$5,520
-
lb
|
$(-1,600.0) | $49,600 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Primary Product Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs