Assessment Year 1995
Principal Product Steel Pipe Couplings
NAICS
n/a
SIC 3498: Fabricated Pipe and Pipe Fittings
Sales Range $50
M
to 100
M
# of Employees 100
Plant Area 130,000
ft2
Annual Production 24,700,000
lb
Production Hrs. Annual 7,509
hrs
Location (State) Arkansas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $356,023 6,283,118
kWh
Natural Gas $29,284 7,578
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $33,784 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $32,816

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings Water Disposal Savings Water Consumption Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $997 $380 $997
14,947
kWh
- - -
02 2.7111: Reduce illumination to minimum necessary levels $14,786 $900 $14,786
296,600
kWh
- - -
03 2.4111: Utilize energy-efficient belts and other improved mechanisms $1,829 - $1,829
40,152
kWh
- - -
04 2.1233: Analyze flue gas for proper air/fuel ratio $490 $1,000 - $490
-
MMBtu
- -
05 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $3,615 $300 $3,615
73,271
kWh
- - -
06 2.4221: Install compressor air intakes in coolest locations $1,364 $400 $1,364
27,550
kWh
- - -
07 2.4133: Use most efficient type of electric motors $8,172 $16,900 $8,172
141,852
kWh
- - -
08 2.4239: Eliminate or reduce compressed air usage $968 $400 $968
19,637
kWh
- - -
09 2.2113: Repair or replace steam traps $420 $100 - $420
-
MMBtu
- -
10 3.4151: Minimize water usage $1,143 $100 - - $587
-
Tgal
$556
-
Tgal
TOTAL RECOMMENDED $33,784 $20,480 $31,731
614,009
kWh
$910
-
MMBtu
$587
-
Tgal
$556
-
Tgal
TOTAL IMPLEMENTED $32,816 $20,080 $30,763
594,372
kWh
$910
-
MMBtu
$587
-
Tgal
$556
-
Tgal
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings Water Disposal Savings Water Consumption Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs